Appendix 1. PARAMETER LISTING
The Drive control circuits use various parameters to select functions and characteristics of the
Drive. Changing of parameter settings must be done in the Program mode, or by use of the
Function LEDs, if available (see Section 4).
The following table lists all parameters in numerical order. For each parameter, reference
paragraph(s) in Section 5 are listed (if applicable) where the features of the Drive affected by that
parameter are described.
PARA-
METER
NAME
n001
Parameter Selection /
Initialization
n002
Control Method Selection
n003
Operation Method Selection
n004
Reference Selection
n005
Stop Method
n006
Reverse Prohibit
n007
STOP Key Function
Reference Selection -
n008
Digital Operator
Frequency Reference Setting
n009
Method From Digital Operator
Operation Selection
n010
When Digital Operator is
Disconnected
n011
Frequency - Max.
n012
Voltage - Max.
Frequency - Max.
n013
Voltage Point
n014
Frequency - Midpoint
Voltage - Midpoint
n015
n016
Frequency - Min.
Voltage - Min.
n017
Table A1-1. V7 Parameters
SETTING RANGE
(AND UNITS)
0:
n001 can be read and set;
n002 - n179 read only
1:
n001 - n039 can be read and set
2:
n001 - n079 can be read and set
3:
n001 - n119 can be read and set
4:
n001 - n179 can be read and set
5:
n001 - n179 can be read and set
Run command accepted during Program mode
6:
Clear Fault History Only
7:
Not Used
8:
2-wire Initialization (Japan Spec.)
9:
3-wire Initialization (Japan Spec.)
10: 2 wire initialization (USA Spec)
11: 3 wire initialization (USA Spec.)
0:
V/f Control
1:
Open Loop Vector
0:
Digital Operator
1:
Terminal
2:
Serial Communication (Modbus)
3:
Option Card
0:
Digital Operator Pot
1:
Digital Operator
2:
Voltage Reference (0 to 10V)
3:
Current Reference (4 to 20 mA)
4:
Current Reference (0 to 20 mA)
5:
Pulse Train Reference
6:
Serial Communications (Modbus)
7:
Multi-Function Analog Input (0 to 10V)
8:
Multi-Function Analog Input (4 to 20 mA)
9:
Option Card
0:
Ramp to stop
1:
Coast to stop
0:
Reverse Run enabled
1
1:
Reverse Run disabled
0:
STOP key is effective regardless of
programming of n003
1:
STOP key is effective only when sequence
command (per n003) is from Digital Operator
0:
Frequency Reference from digital
operator pot
1:
Frequency Reference from n024
0:
ENTER key must be pressed to write-in
new value
1:
ENTER key does not have to be pressed
to write-in new value
0:
Disabled (operation continues)
1:
Enabled (motor coasts to a stop and fault
is displayed)
50.0 to 400.0
0.1 to 255.0 (230V drive)
0.2 to 510.0 (460V drive)
0.2 to 400.0
0.1 to 399.9
0.1 to 255.0 (230V drive)
0.2 to 510.0 (460V drive)
0.1 to 10.0
0.1 to 50.0 (230V drive)
0.2 to 100.0 (460V drive)
A1-1
SETTING
FACTORY
USER
INCREMENT
SETTING
SETTING
1
1
1
0
1
1
1
2
1
0
0
1
0
1
0
1
0
1
0
0.1 (Hz)
60.0
230.0
0.1 (V)
460.0
0.1 (Hz)
60.0
0.1 (Hz)
(Note 2)
0.1 (V)
(Note 2)
0.1 (Hz)
(Note 2)
0.1 (V)
(Note 2)
PARA.
REF.
5.21
2.2
5.13
5.11,
5.13
5.24
5.13
5.13
5.13
5.15
5.27