YASKAWA V7 Technical Manual page 103

Hide thumbs Also See for V7:
Table of Contents

Advertisement

5.29 COPY FUNCTION
F.
Copy Function message list
Operator Description
display
rdy
Drive is ready to perform a Copy Function
rEd
Read selected
Flashing: Read is being performed
Cpy
Writing (COPY) selected
Flashing: Write (Copy) is being performed
uFy
Verify selected
Flashing: Verify is being performed
uA
Drive capacity selected
Sno
Software number displayed
End
Read, Copy or Verify completed
PrE
Flashing: Attempt to execute Read while
parameter Copy Access Selection (n177)
is set to " 0"
rdE
Flashing: Parameter could not be read
properly by the Read function, or, an
under voltage is detected during Read
CSE
Flashing A check sum error occurred in
the parameter data stored in the digital
operator
dpS
Flashing: Parameter data in the drive
and in the digital operator do not match.
(Ex.) Copying from a GPD 315/V7 and
writing to a GPD 305/J7
ndr
Flashing: No parameter data is stored
in the digital operator
CPE
Flashing: Attempt to execute a Copy
or Verify between different voltage drives
or a different Control Mode
CyE
Flashing: An under voltage is detected
during a Copy execution
F04
A check sum error occurs in the
parameter data stored in the inverter
uAE
Flashing: Attempt Execute Verify
between different drive capacities
.FE
Flashing: A communication error has
occurred between the digital operator
and the drive
Continued
5-51
Corrective action
-
-
-
-
-
-
-
Set Parameter n177 to a value of "1"
Confirm that the main circuit power supply
voltage is correct, then re-execute a Read
The parameter data stored in the digital
operator is invalid and cannot be used.
Re-execute Read to store the parameters in
the digital operator
Check to see if the drives are the same type
Execute a Read
Verify Voltage and Control Modes
Confirm that the main circuit power supply
voltage is correct, then-execute a Copy
Initialize the constants. If an error occurs
again, replace the inverter due to a failure of
parameter memory element (EEPROM) in
the drive
Press the Data/Enter key to continue the
execution of Verify. Press stop to interrupt the
execution of Verify
Check the connection between the drive and
the digital operator. If a communication error
occurs be sure to re-execute Read or Copy