YASKAWA V7 Technical Manual page 88

Hide thumbs Also See for V7:
Table of Contents

Advertisement

5.23 STALL PREVENTION
D.
n115 : Stall Prevention Above Base Speed During Running
Setting
0
1
E.
n116 : Stall Prevention During Run, Accel/Decel Time Select
Setting
0
1
Continued
Function
Disabled (level is based on setting of n094)
Enabled (level at Fmax, n011, is n094 x 0.4)
Function
Follows accel/decel #1 (n019, n020) or accel/decel #2
(n021,n022)
Note: Multi-Function input selectable
Follows accel/decel #2 (n021,n022) always
5-36
Factory setting: 0
Range: 0 or 1
Factory setting: 0
Range: 0 or 1