1.3 PHYSICAL INSTALLATION
30mm
1. To use 5.5/5.7 kw (7.5/10 Hp) Drives as open chassis, remove both top and bottom covers.
2. The clearances required at top/bottom and both sides are common in open chassis type
(IP00) and enclosed wall-mounted type (IP20).
3. For the external dimensions and mounting dimensions, refer to the "DIMENSIONS" section
of Appendix 5.
4. Allowable intake air temperature to the Drive:
Open chassis type:
Enclosed wall-mounted type:
5. Allow sufficient space for the sections at the upper and lower parts marked with * in order to
permit the flow of intake/exhaust air to/from the Drive.
Continued
(100mm)
30mm
(100mm)
-10°C to +50°C
-10°C to +40°C
1-2
3.94 in.
3.94 in.
AIR
AIR