DataCard CR825 Installation And Administrator's Manual page 99

Instant issuance system
Table of Contents

Advertisement

Description
14) WriteTrack1
15) WriteTrack2
16) WriteTrack3
Change settings as needed, and then click Set Current to apply changes.
Attempts—Specify the number of attempts (automatic retries) the printer makes to encode

the magnetic stripe data. This value also is used for the number of times to attempt to read
magnetic stripe data.
If you set this number to a lower value, it increases the throughput of the printer but can
decrease the reliability of magnetic stripe encoding.
If you set the number to a higher value, it decreases the throughput of the printer but can
increase the reliability of magnetic stripe encoding.
A value of 1 means no retry attempts.
Coercivity—Select the coercivity setting that matches the cards you are using. Coercivity

measures the resistance of magnetic material to the removal of encoded data. High coercivity
(HICO) requires more electrical force to encode data and the data is more resistant to
magnetic interference. The choices are HICO, LOCO, NTT1, NTT2, NTT3.
DataFormat (1, 2, 3)—Specify the names of the data formats used for tracks 1, 2, and 3.

For single-track magnetic stripe encoding, set DataFormat3 to JIS and DataFormat1 and
DataFormat2 to NONE.
To use a custom data format, define the formats for tracks 1, 2, and/or 3 using the
MagStripeCustomTrack (1, 2, 3) settings and then set the corresponding DataFormat settings
to CUSTOM.
NoDataDisableTrack—Disable the magnetic stripe write head for a track if the track contains

no data. When this is disabled, any track that was not given data is erased.
ReadTrack (1, 2, 3)—Allow magnetic stripe read actions to read from tracks 1, 2, and 3.

SSA (1, 2, 3)—Set the start sentinel adjustment for tracks 1, 2, and 3. (SSA3 also sets the start

sentinel for a single track.) The start sentinel is encoded on the magnetic stripe immediately
before the first data character and indicates the beginning of data. Enter a value from -4 to 4.
StripeEncoderMultiplier—This value is information only and cannot be changed. It is

determined when an SSA test is run.
WriteTrack (1, 2, 3)—Allow magnetic stripe write actions to write to tracks 1, 2, and 3.

CR825 and CE875 Instant Issuance System Installation and Administrator's Guide
Default
Current
Value
Value (unit)
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Allowed
Range
83