Electrical system
TABLE ZF
Place the connector on the opposite side of the
control unit and lower the driving lever until the
"click" that signals the end of the stroke is heard
TABLE ZG
When the connector is fully inserted, the distance between the connector and the ABS control unit must
be 7.5 mm (0.29 in).
If the initial position of the connector and the driving lever is not as shown in figure ZE, the connector
will not get properly coupled and the distance measured will be longer (12 mm approx. (0.47 in)).
In this case, repeat the operation as described in the ZF-ZG picture.
It is advisable to create a jig in order to check the correct connector insertion.
ELE SYS - 104