10.2 Work Items, Work Assignment, and Work Time
"Table 10.2" lists the work items, standard work time, and the person in charge of these types of work.
Work item
Checking the delivered items
Installing option
Verifying operation
Preparation of handing over to
the System Administrator
Handover to the system administrator
SET1003000
10.3 Procedure for installing IOUB
SET1003010
10.3.1 Checking the delivered items
(1) Check the delivered items by confirming the following.
1. The types and quantities of delivered options match those written on the order sheet.
2. The delivered items match those listed in the List of Accessories.
3. All cabinets are free of any abnormalities such as scratches, dents, or dirt.
4. The specifications and version level of units delivered separately due to delivery considerations
are available for the target functions.
(2) Proceed to
SET1003020
10.3.2 Installing option
Install according to the following procedures.
ANNT)
- The installation location and quantity have to indicate by the system administrator.
- Confirm connecting position of power cable of the Base Unit beforehand.
(1) Turn off AC power of the Base Unit.
(2) Remove the IOU dummy.
(3) To install PCI card at the same time, remove PCI card dummy of IOUB install PCI card.
See chapter 5
(4) Install the IOUB.
See Appendix F.3.1
(5) Turn on AC power of the Base Unit.
→ Wait until green indicator of the "System Power" turns off.
(6) Make sure that the Alarm indicator of the IOUB is not lit. (See "Figure 10.3.2".)
"10.3.2 Installing
option".
"Installing PCI
Card".
"Installing
IOUB".
Table 10.2
Person in charge
Service engineer
Service engineer
Service engineer
Service engineer
System administrator and
Service engineer
67
Work time
(minute)
5
10
15
1
5