Table Position Adjustment: Only For 6030 - JUKI AMS-224EN-4530 Instruction Manuals

Table of Contents

Advertisement

Within 0.3 mm

3-2. Table position adjustment: Only for 6030

For the 6030, the table has been retracted from the normal position in the factory in prior to shipment.
After unpacking, be sure to carry out the following steps 1) through 9).
L
A
B
– 4 –
1. Fix the throat plate auxiliary
cover ❸ so that is higher
than the throat plate ❷ (within
0.3 mm). When it is lower
than the throat plate ❷ , nee-
dle breakage or the like due
to the defective feed will be
caused.
2. Confirm by putting a ruler or
the like that the throat plate
auxiliary cover ❸ is horizon-
tally installed. If not, throat
plate auxiliary cover ❸ and
lower plate ❶ come in con-
tact partially with each other,
and abnormal worn-out will
be caused.
Position adjustment for the
left table L is described as an
example. Adjust the position of
R
the right table R in the similar
manner.
[Accessories to be used]
A: Table fixing bolt cover
HX00326000B x 2
B: Power switch setscrew
SK3512001SE x 2
(Four setscrews are used for the table of the
machine for JE.)
1) Remove screws ❶ and ❷ to remove the cover.
* When removing screw ❷ , take care not to lose
the nut secured on the underside of the table.