Table Position Adjustment: Only For 6030 - JUKI AMS-224EN/IP-420 Instruction Manual

Table of Contents

Advertisement

Within 0.3 mm
2

3-2. table position adjustment: only for 6030

For the 6030, the table has been retracted from the normal poston n the factory n pror to shpment.
After unpackng, be sure to carry out the followng steps ) through 9).
L
a
1
2
1
3
B
– 4 –
1. Fix the throat plate auxiliary
cover 3 so that is higher
than the throat plate 2 (within
0.3 mm). When it is lower
3
than the throat plate 2 , nee-
dle breakage or the like due
to the defective feed will be
caused.
2. Confirm by putting a ruler or
the like that the throat plate
auxiliary cover 3 is horizon-
tally installed. If not, throat
3
plate auxiliary cover 3 and
lower plate 1 come in con-
tact partially with each other,
and abnormal worn-out will
be caused.
Poston adjustment for the
left table L s descrbed as an
example. Adjust the poston of
r
the rght table r n the smlar
manner.
[accessories to be used]
a: Table fixing bolt cover
HX00326000B x 2
B: Power swtch setscrew
SK35200SE x 2
(Four setscrews are used for the table of the
machne for JE.)
) Remove screws 1 and 2 to remove the cover.
* When removng screw 2 , take care not to lose
the nut secured on the undersde of the table.