JUKI AMS-224EN-4530 Instruction Manuals page 34

Table of Contents

Advertisement

F
1. When turning OFF the power without pressing READY key
tern No.", "X enlargement/reduction ratio", "Y enlargement/reduction ratio", "Max. sewing
speed", "Thread tension" or "Intermediate presser height" is not stored in memory.
2. When operation processing cannot be performed since the reduction ratio is excessively
small, E042 Operation error is displayed.
3. When the scale rate is changed with increase/decrease of number of stitches (pitch is
fixed), mechanical control command inputted to the points other than the shape point is
deleted.
H
For example, input X scale rate.
A to display the item data input screen.
Press
③ Input the data.
Input the value you desire with ten keys and + / – keys F.
④ Determine the data.
When ENTER button
mined.
*
For the other item data, the data can be changed by the
G
same operation.
*
X/Y scale rate or X/Y actual size value can be inputted in
one screen.
When X/Y enlargement/reduction ratio, thread tension, intermedi-
ate presser, adding/deleting of thread tension command, or adding/
deleting of increase/decrease value of intermediate presser of us-
ers' pattern or media pattern is performed, the pattern kind section
becomes change display H.
In case of change display H, the change confirmation screen is
displayed at the time of the change of pattern.
When ENTER button
current pattern is invalidated and the pattern No. is changed.
To store the changed pattern, refer to
register of users' pattern"
I
– 30 –
G is pressed, the data is deter-
, the set value of "Pat-
I is pressed, the information on the
"II-2-13. Performing new