Sony BVW-55 Maintenance Manual page 83

Hide thumbs Also See for BVW-55:
Table of Contents

Advertisement

C000 : CASSETTE SW
This submenu checks the functions of cassette tab sensors and REC inhibit sensors
(switches).
(1) Press each sensor (switch) with fingers.
. Confirm that "0" below the corresponding switch number changes to "1".
(2) Release the fingers.
. Confirm that "1" below the corresponding switch number returns to "0".
(3) Press the MENU button when terminating the check.
In case of NG
When cassette tab sensors (1 to 6) are NG
. Check the corresponding sensor (S400 to S405) on the SV-206 board.
. Check the sensor input port of MPU (IC402 on the SV-206 board).
When REC inhibit sensor (METAL tape) 7 is NG
. Check the sensor (S406) on the SV-206 board.
. Check the sensor input port of MPU (IC402 on the SV-206 board).
When REC inhibit sensor (OXIDE tape) 8 is NG
. Check the sensor (PH400) on the SV-206 board.
. Check the sensor input port of MPU (IC402 on the SV-206 board).
7 REC
inhibit
sensor
(METAL tape)
BVW-55
Locations of Sensors (Switches)
3-2. TAPE Maintenance Mode (M0)
3-2-2. SERVO CHECK Mode (C0)
INPUT CHECK
C000:CASSETTE SW
1:REEL HUB
3:THICKNESS 4:SPARE
5:SPARE
7:METAL REC INHIBIT
8:OXIDE REC INHIBIT
SW 87654321
00000000
(Ex.: When pressing the switch 7)
INPUT CHECK
C000:CASSETTE SW
1:REEL HUB
3:THICKNESS 4:SPARE
5:SPARE
7:METAL REC INHIBIT
8:OXIDE REC INHIBIT
SW 87654321
00000000
Cassette tab sensors
1
3
42
5
6
1 Reel hub sensor
2 Metal/oxide tape sensor
3 Tape thickness sensor
4 Spare sensor 2
5 Spare sensor 1
6 Degital/analog tape sensor
8 REC inhibit sensor
(OXIDE tape)
2:METAL/OX
6:DGTL/ANLG
7
1 3 8
425
6
2:METAL/OX
6:DGTL/ANLG
7
1 3 8
425
6
3-11