Set button: Sets consistency group options.
1.
Connect to the MCU.
2.
Split all pairs in the group (Pairsplit-r).
3.
From the Consistency Group tree, click a consistency group mode that includes the consistency
group to be modified.
4.
From the Consistency Group list, click the consistency groups to be modified. Select more than one
consistency group with MCU in the This CU column.
5.
Right-click, click CT Group Operation, and click CT Group Option. The CT Group Option pane
appears. If the CT Group Option command is not enabled, split the remaining pairs in this
consistency group.
6.
Change group options as needed.
7.
Click Set in the CT Group Option pane. The CT Group Option pane closes, and the list changes to
the Consistency Group Settings Parameter list. Settings are applied to the list.
NOTE:
After being set, options can be modified and canceled (see
deleting consistency
8.
Click Apply on the Continuous Access XP main pane to apply settings to the disk array.
9.
When you are finished changing group options, resync all pairs in the group (pairresync).
When the CT Group Option pane is closed, the list changes to the Consistency Group Settings Parameter
list.
Figure 43 Consistency Group Settings Parameter list
CTG: Consistency group number
M-R Path: Channel type
Time Out (Pending): Copy pending time out (maximum delay) allowed for Continuous Access
XP Async copy (in minutes)
Time Out (Ready): RCU ready timeout (maximum delay) allowed for re-establishing MCU-RCU
communications following MCU power-off (in minutes)

Deleting consistency groups (Delete CT Group)

A consistency group can be deleted only from the MCU and only if the MCU does not contain P-VOLs
still assigned to the group. Deleting a consistency group from an MCU does not affect consistency
groups registered at other MCUs. The RCU automatically deletes a consistency group when the last
volume pair in the group is deleted.
Use the Delete CT Group command to delete the selected group from the current MCU.
1.
Connect to the MCU.
2.
From the Consistency Group tree, click a consistency group mode that includes the consistency
group to be deleted.
3.
From the Consistency Group list, click the consistency groups to be deleted. Select more than one
consistency group with MCU in the This CU column.
4.
Right-click, click CT Group Operation, and click Delete CT Group. The list changes to the Consistency
Group Settings Parameter list. If the Delete CT Group command is not enabled, the selected group
still contains P-VOLs in this MCU.