Rcu Settings Parameter List - HP StorageWorks XP12000 User Manual

Continuous access xp
Hide thumbs Also See for StorageWorks XP12000:
Table of Contents

Advertisement

HP representative can also get the RCU S/N and SSIDs using the RCU's service processor (at
the remote site).
2.
In the RCU Operation pane, click MCU&RCU in the Switch Display box.
3.
In the CU number/Port tree, click the correct CU image. For this step, the list can be blank. You must
register and add RCUs to each CU image separately.
4.
In the MCU/RCU list, right-click. For registering RCU operations, the RCU does not have to be
selected on the list.
5.
In the pop-up menu, click RCU Operation, and click Add RCU. The Add RCU pane appears.
6.
Enter the RCU's S/N and the CU image's Controller ID, CU number, and SSIDs or Path Gr. ID. Enter
the value in hexadecimal within the range of 1 to FF for Path Gr. ID or use the default value. Up
to 64 Path Gr. IDs can be registered per subsystem. The MCU verifies the S/N when paths are
established, and verifies the SSIDs when volume pairs are created. If needed, add and delete SSIDs
later using the Add SSID pane (see
7.
Click the MCU and RCU ports from the drop-down lists. The MCU will not establish less than the
minimum number of paths as specified on the RCU Option pane (see
(Change RCU
Option)). If needed, you can add and delete paths later by using the Add Path pane
(see
Adding and deleting logical paths for RCUs (Add Path/Delete
8.
Click Option to open the RCU Option pane. Click Cancel to cancel settings made on the Add
RCU pane.
9.
From the RCU Option pane, enter or select the settings for Minimum Paths, Maximum Initial Copy
Activity, and RIO MIH Time. For Fibre Channel interface, also specify the Path Blockade Watch
setting.
10.
In the RCU Option pane, click Set (even if you made no changes). Click Cancel to cancel the
settings. The list changes to the RCU Settings Parameter list.
1 1.
The new RCU is displayed in the RCU Settings Parameter list. To check the path status for this RCU,
select the RCU, right-click, and click RCU Status. For more information about path status, see the
Troubleshooting chapter of the HP StorageWorks Command View XP user guide for XP Disk Arrays
or the HP StorageWorks XP Remote Web Console user guide for XP12000/XP10000.
NOTE:
After being set, options can be modified and canceled (see
When the pair option is set (the RCU Option pane is closed), the list changes to the RCU Settings
Parameter list.
Figure 32
Figure 32 RCU Settings Parameter list
S/N: RCU serial number
SSID 1 to SSID 4: Selected SSID: SSID 1 to SSID 4
M-R Path: Channel type
Num. of Path: Number of the paths used
MCU Port 1 to MCU Port 8: Port number on the MCU side: 1 to 8
RCU Port 1 to RCU Port 8: Port number on the RCU side: 1 to 8
Min.Path: Minimum number of paths required for each RCU connected to the current MCU
Activity: Number of concurrent initial copy operations
MIH Time: Time value for the remote I/O (RIO) missing interrupt handler (MIH)
78
Continuous Access XP for the Array
Adding and deleting SSIDs for RCUs (Add SSID/Delete
shows the items in the RCU Settings Parameter list.
Modifying RCU options
Path)).
Modifying parameters and deleting
SSID)).
settings).