Modifying Rcu Options (Change Rcu Option) - HP StorageWorks XP12000 User Manual

Continuous access xp
Hide thumbs Also See for StorageWorks XP12000:
Table of Contents

Advertisement

Path Watch: Time for monitoring blockade in the Fibre Channel paths on the MCU side

Modifying RCU options (Change RCU Option)

Use the RCU Options pane to modify RCU options set when you registered the RCU. When the RCU
Option pane is opened with the Change RCU Option command, all fields are blank. You must fill in the
fields you need to modify; it is not necessary to fill in all fields. Fields left blank keep settings made for
the registering RCU operation.
RCU options apply to all CU images of the current MCU and all RCUs connected to the MCU.
Figure 33 RCU Option pane
For further information about the RCU Option pane, see
1.
In the CU number/Port tree on the RCU Operation pane, ensure that the correct CU image is selected.
2.
From the MCU/RCU list, click the RCU you want to modify.
3.
Right-click, click RCU Operation, and click Change RCU Option. The RCU Option pane appears.
4.
Modify RCU options. When the RCU Option pane is open, all fields are blank. Fill in the fields
you want to modify.
5.
Click Set to set the modifications. The list changes to the RCU Settings Parameter list (RCU Option)
view. Click Cancel to cancel all modifications you made.
NOTE:
After being set, options can be modified and canceled (see
deleting
settings).
6.
Click Apply on the Continuous Access XP main pane to apply the modification to the disk array.
When modifications are set (the RCU Option pane closes), the MCU/RCU list changes to the RCU Settings
Parameter list (RCU Option).
Figure 34 RCU Settings Parameter list (RCU Option)
S/N and SSID: RCU serial number and SSID
M-R Path: Channel type
Min.Path: Minimum number of paths required for each RCU connected to the current MCU
Activity: Number of concurrent initial copy operations
MIH Time: Time value for the remote I/O (RIO) missing interrupt handler (MIH)
Path Watch: Time for monitoring blockade in the Fibre Channel paths on the MCU side
Figure 34
shows the items om the RCU Settings Parameter list (RCU Option).
Registering RCUs (Add
RCU).
Modifying parameters and
Continuous Access XP user guide