Modifying Consistency Group Options (Ct Group Option); Ct Group Option Pane - HP StorageWorks XP12000 User Manual

Continuous access xp
Hide thumbs Also See for StorageWorks XP12000:
Table of Contents

Advertisement

NOTE:
After being set, options can be modified and canceled (see
deleting consistency
8.
Click Apply on the Continuous Access XP main pane to apply settings to the disk array.
When the Add CT Group pane closes, the list changes to the Consistency Group Settings Parameter
list. However, columns other than CTG are blank. For further information about the Consistency Group
Settings Parameter list, see

Modifying consistency group options (CT Group Option)

Use the CT Group Option command to modify consistency group options set when you added the
consistency group. When the CT Group Option command is selected, the CT Group Option pane
appears. The CT Group Option pane consists of the same fields as the Add CT Group pane (see
consistency groups (Add CT
NOTE:
To change group options, split all pairs in the group first.
Figure 42 CT Group Option pane
MCU-RCU Path: Selected port type for remote copy connections. You cannot change the port
type on the CT Group Option pane.
Time Out (Copy Pending) (min.): Maximum delay (copy pending timeout) allowed for Continuous
Access XP Async copy (none or from 1 to 15 minutes; none = no timeout for Continuous Access
XP Async copy pending). The default is five minutes. If the delay between the Continuous Access
XP Async P-VOL update and corresponding S-VOL update reaches the specified time, the RCU
suspends all S-VOLs in the group. A timeout occurs when the RCU cannot settle a recordset
within the specified time or has not had any communications from one of the MCUs in the group
within the specified time.
NOTE:
The copy pending timeout value should be less than the I/O timeout value of the host system.
Time Out (RCU Ready) (min.): Maximum delay allowed for re-establishing MCU-RCU
communications following MCU power-off (none or from 1 to 10 minutes; none = no timeout
for Continuous Access XP Async RCU ready). The default is five minutes. If the MCU cannot
re-establish communications with the RCU within the specified time, the MCU suspends all
P-VOLs in the group.
Cancel button: Cancels settings.
groups).
Modifying consistency group options (CT Group
Group)).
Modifying parameters and
Option).