Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
Command
set ser_flow 1 hw
set ser_flow 1 none
System Parameters
A - 114
ser_flow RS-232 Flow Control
Argument
Channel Type
Value Type
Read/Write Mode
Values
Description
This parameter sets the type of flow control that will be used on the RS-232
port. Hardware flow control is recommended for baud rates over 9600 bps.
Examples
Response
val ser_flow 1 hw
val ser_flow 1 none
dev_bootloader_ver Bootloader Version
Argument
Channel Type
Value Type
Read/Write Mode
System Limits
Description
This parameter returns the bootloader version.
Argument value
Device-Specific System
List
Read/Write
none : No flow control (default)
hw : Hardware flow control (RTS/CTS)
Description
Sets the serial port flow control on device 1 (the first
device) to 'hw'.
Disables the serial port flow control on device 1 (the first
device) by setting the flow control to 'none'.
Argument value
Device-Specific System
String
Read-Only
Max String Length: 24