Parameter Group H - Omron 3G3MX2 Quick Start Manual

Born to drive machines; 200 v class three-phase input 0.1 to 15 kw; 200 v class single-phase input 0.1 to 2.2 kw; 400 v class three-phase input 0.4 to 15 kw
Hide thumbs Also See for 3G3MX2:
Table of Contents

Advertisement

MX2 Quick Start Guide
Function code
Function name
C102
Reset mode selection
C103
Restart mode after reset
C104
UP/DWN clear mode
C105
FM gain adjustment
C106
AM gain adjustment
C109
AM bias adjustment
C111
Overload warning level 2
C130
Output [11] on-delay time
C131
Output [11] off-delay time
C132
Output [12] on-delay time
C133
Output [12] off-delay time
C140
Output RY on-delay time
C141
Output RY off-delay time
C142
Logic output 1 operand A
C143
Logic output 1 operand B
C144
Logical output 1 operator
C145
Logic output 2 operand A
C146
Logic output 2 operand B
C147
Logical output 2 operator
C148
Logic output 3 operand A
C149
Logic output 3 operand B
C150
Logical output 3 operator
C160
Input [1] response time
C161
Input [2] response time
C162
Input [3] response time
C163
Input [4] response time
C164
Input [5] response time
C165
Input [6] response time
C166
Input [7] response time
C169
Multistage speed/position determination time

4.5 Parameter group H

Function code
Function name
H001
Auto-tuning Setting
H002
Motor data selection, 1st motor
H003
Motor capacity, 1st motor
H004
Motor poles setting, 1st motor
H005
Motor speed constant, 1st motor
H006
Motor stabilization constant, 1st motor
H020
Motor constant R1, 1st motor
H021
Motor constant R2, 1st motor
H022
Motor constant L, 1st motor
H023
Motor constant Io
H024(32-bits)
Motor constant J
H030
Auto constant R1, 1st motor
H031
Auto constant R2, 1st motor
H032
Auto constant L, 1st motor
H033
Auto constant Io, 1st motor
H024(32-bits)
Auto constant J, 1st motor
H050
Slip compensation P gain for V/f control with FB
H051
Slip compensation P gain for V/f control with FB
H102
PM motor code setting
H103
PM motor capacity
H104
PM motor poles setting
42
Monitoring and setting items
00 (resetting the trip when RS is on), 01 (resetting the
trip when RS is off), 02 (enabling resetting only upon
tripping [resetting when RS is on]), 03(resetting only
trip)
00(starting with 0 Hz), 01(starting with matching fre-
quency), 02(restarting with active matching freq)
00 (0Hz)/01 (EEPROM data)
50 to 200
50 to 200
0 to 100
0 to 2000
0 to 1000
0 to 1000
0 to 1000
0 to 1000
0 to 1000
0 to 1000
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6, OPO, no)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6, OPO, no)
0 (AND), 1 (OR), 2 (XOR)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6, OPO, no)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6, OPO, no)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6, OPO, no)
Same as the settings of C021 to C026 (except those of
LOG1 to LOG6, OPO, no)
00 (AND), 01 (OR), 02 (XOR)
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
Monitoring and setting items
00 (disabling auto-tuning), 01 (auto-tuning without
rotation), 02 (auto-tuning with rotation)
00 (Standard motor data), 02 (auto-tuned data)
00(0.1kW)- 15 (18.5kW)
0 (2 poles), 1 (4 poles), 2 (6 poles),3 (8 poles), 4 (10)
1 to 1000
0 to 255
1 to 65530
1 to 65530
1 to 65530
1 to 65530
1 to 9999000
1 to 65530
1 to 65530
1 to 65530
1 to 65530
1 to 9999000
0 to 10000
0 to 10000
00 (Standard motor data), 01(auto-tuned data)
0.1/0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.0/3.7/4.0/5.5/7.5/
11.0/15.0/18.5
2(0)/4(1)/6(2)/8(3)/10(4)/12(5)/14(6)/16(7)/18(8)/
20(9)/22(10)/24(11)/26(12)/28(13)/30(14)/32(15)/
34(16)/36(17)/38(18)/40(19)/42(20)/44(21)/46(22)/
48(34) pole
Units
Run
Modbus
Default
mode
Register
edit
No.
146Ah
146Bh
146Ch
1 [%]
146Dh
100
1 [%]
146Eh
100
1 [%]
1471h
0.1 [%]
1473h
0.1 [sec.]
1486h
0.1 [sec.]
1487h
0.1 [sec.]
1488h
0.1 [sec.]
1489h
0.1 [sec.]
1490h
0.1 [sec.]
1491h
1492h
1493h
1494h
1495h
1496h
1497h
1498h
1499h
149Ah
-
14A4h
-
14A5h
-
14A6h
-
14A7h
-
14A8h
-
14A9h
-
14AAh
-
14ADh
Units
Run
Modbus
Default
mode
Register
edit
No.
1501h
1502h
1503h
1504h
1[%]
1506h
1
1507h
0.001 []
1516h
0.001 []
1518h
0.01 mH
151Ah
0.01 [A]
151Ch
0.001
151Dh
151Eh
0.001 []
1525h
0.001 []
1527h
0.01 mH
1529h
0.01 [A]
152Bh
0.001
152Ch
152Dh
0.1
153Dh
1
153Eh
1571h
1572h
1573h
MX2 Quick Start Guide
00
00
00
0
-
0.0
0.0
0.0
0.0
0.0
0.0
00
00
00
00
00
00
00
00
00
1
1
1
1
1
1
1
0
00
00
-
4P
100
100
-
-
-
-
-
-
-
-
-
-
0.20
2
00
-
4P