Parameter Group A - Omron 3G3MX2 Quick Start Manual

Born to drive machines; 200 v class three-phase input 0.1 to 15 kw; 200 v class single-phase input 0.1 to 2.2 kw; 400 v class three-phase input 0.4 to 15 kw
Hide thumbs Also See for 3G3MX2:
Table of Contents

Advertisement

MX2 Quick Start Guide
Function code
d010
Torque bias monitor
d012
Torque monitor
d013
Output voltage monitor
d014
Power monitor
d015 (32-bits)
Watt-hour monitor
d016 (32-bits)
Elapsed RUN time monitor
d017 (32-bits)
Elapsed power-on time monitor
d018
Heat sink temperature monitor
d022
Life-check monitor
d023
Drive programming program counter
d024
Drive programming program number
d025(32-bits)
User monitor 1
d026(32-bits)
User monitor 2
d027(32-bits)
User monitor 3
d029(32-bits)
Position setting monitor
d030(32-bits)
Position feedback monitor
d60
Inverter mode monitor
d80
Trip counter
d081
Trip info 1
d082
Trip info 2
d083
Trip info 3
d084
Trip info 4
d085
Trip info 5
d086
Trip info 6
d090
Warning monitor
d102
DC voltage monitoring (across P and N)
d103
BRD load factor monitoring
d104
Electronic thermal overload monitoring

4.2 Parameter group A

Function code
Function name
A001
Frequency source
A002
Run command source (*)
A003
Base frequency
A004
Maximum frequency
A005
[AT] selection
A011 (32-bits) [O] input active range start frequency
A012 (32-bits) [O] input active range end frequency
A013
[O] input active range start voltage
A014
[O] input active range end voltage
A015
[O] input start frequency select
A016
Analog input filter.
A017
EzSQ selection
A019
Multi speed operation selection
A020 (32-bits) Multi-speed freq. 0
A021 (32-bits) Multi-speed freq. 1
36
Function name
0 (keypad potentiometer), 1 (control circuit terminal
block), 2 (digital operator), 3 (Modbus), 4 (option ), 6
(pulse train input), 7 (easy sequence), 10 (operation
function result)
1 (control circuit terminal block), 2 (digital operator), 3
(Modbus), 4 (option)
300 to "maximum frequency"
300 to 4000 (10000)
0 (switching between O and OI terminals), 2 (switching
between O terminal and keypad potentiometer), 3
(switching between OI terminal and keypad potentiom-
eter)
0 to 40000(100000)
0 to 40000(100000)
0 to "[O]-[L] input active range end voltage"
"[O]-[L] input active range start voltage" to 100
00 (external start frequency), 01 (0 Hz)
1 to 30 or 31 (500 ms filter ±0.1 Hz
with hysteresis)
00 (disabling), 01 (PRG terminal) , 02 (Always)
00 (binary), 01 (bit)
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
Monitoring and setting items
-200 to +200
-200 to +200
0 to 6000
0 to 1000
0 to 9999000
0 to 999900
0 to 999900
-200 to 1500
2^0: Capacitor on main circuit board
2^1: cooling-fan
0~1024
0~9999
-2147483647 to 2147483647
-2147483647 to 2147483647
-2147483647 to 2147483647
-268435455 to 268435455
-268435455 to 268435455
0 (IM CT)
2(IM High Freq mode)
1(IM VT)
0 to 65530
Trip factor
Inverter status
Output frequency (32-bit)
Output current
Output voltage
Running time (32-bit)
Power-on time (32-bit)
Warning code
0 to 10000
0 to 1000
0 to 1000
Monitoring and setting items
Units
Modbus
Register No.
1 [%]
100Eh
1 [%]
1010h
0.1 [V]
1011h
0.1 [kW]
1012h
0.1
1013h
1014h
1 [h]
1015h
1016h
1 [h]
1017h
1018h
0.1 [?]
1019h
1 bit
101Dh
101Eh
101Fh
1
102Eh
102Fh
1
1030h
1031h
1
1032h
1033h
1
1036h
1037h
1
1038h
1039h
1057h
-
0011h
-
0012h to
001Bh
-
001Ch to
0025h
-
0026h to
002Fh
-
0030h to
0039h
-
003Ah to
0043h
-
0044h to
004Ch
-
004Eh
0.1 [V]
1026h
0.1 [%]
1027h
0.1 [%]
1028h
Units
Run
Modbus
Default
mode
Register
edit
1201h
1202h
0.1 [Hz]
1203h
50.0
0.1 [Hz]
1204h
50.0
1205h
0.01 [Hz]
120Bh
0.00
120Ch
0.01 [Hz]
120Dh
0.00
120Eh
1 [%]
120Fh
1 [%]
1210h
100
1211h
1
1212h
1213h
1215h
0.01 [Hz]
1216h
6.00
1217h
0.01 [Hz]
1218h
0.00
1219h
MX2 Quick Start Guide
01
01
00
0
01
8
00
00