PARAMETER LIST
Function code
Function name
A022 (32-bits) Multi-speed freq. 2
A023 (32-bits) Multi-speed freq. 3
A024 (32-bits) Multi-speed freq. 4
A025 (32-bits) Multi-speed freq. 5
A026 (32-bits) Multi-speed freq. 6
A027 (32-bits) Multi-speed freq. 7
A028 (32-bits) Multi-speed freq. 8
A029 (32-bits) Multi-speed freq. 9
A030 (32-bits) Multi-speed freq. 10
A031 (32-bits) Multi-speed freq. 11
A032 (32-bits) Multi-speed freq. 12
A033 (32-bits) Multi-speed freq. 13
A034 (32-bits) Multi-speed freq. 14
A035 (32-bits) Multi-speed freq. 15
A038
Jog frequency
A039
Jog stop mode
A041
Torque boost method selection
A042
Manual torque boost value
A043
Manual torque boost frequency
A044
V/F characteristic curve selection, 1st motor
A045
V/f gain
A046
Voltage compensation gain setting for automatic
torque boost, 1st motor
A047
Slippage compensation gain setting for automatic
torque boost, 1st motor
A051
DC braking enable
A052
DC braking frequency
A053
DC braking wait time
A054
DC braking force during deceleration
A055
DC braking time for deceleration
A056
DC braking/edge or level detection for [DB] input
A057
DC braking force for starting
A058
DC braking time for starting
A059
DC braking carrier frequency setting
A061 (32-bits) Frequency upper limit
A062 (32-bits) Frequency lower limit
A063 (32-bits) Jump freq. (center) 1
A064
Jump freq. width (hysteresis) 1
A065 (32-bits) Jump freq. (center) 2
A066
Jump freq. width (hysteresis) 2
A067 (32-bits) Jump freq. (center) 3
A068
Jump freq. width (hysteresis) 3
A069 (32-bits) Acceleration hold frequency
A070
Acceleration hold time
MX2 Quick Start Guide
Monitoring and setting items
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0 or "start frequency" to "maximum frequency"
0.0, "Start frequency" to 999(10000)
0 (free-running after jogging stops [disabled during
operation])
1 (deceleration and stop after jogging stops [disabled
during operation])
2 (DC braking after jogging stops [disabled during
operation])
3 (free-running after jogging stops [enabled during
operation])
4 (deceleration and stop after jogging stops [enabled
during operation])
5 (DC braking after jogging stops [enabled during
operation])
00 (manual torque boost),
01 (automatic torque boost)
0 to 200
0 to 500
00 (VC), 01 (VP), 02 (free V/f),
03 (sensorless vector control),
20 to 100
0 to 255
0 to 255
00 (disabling), 01 (enabling),
02 (output freq < [A052])
0 to 6000
0 to 50
0 to 100
0 to 600
00 (edge operation),
01 (level operation)
0 to 100
0 to 600
20 to 150
0 or "maximum frequency limit" to "maximum fre-
quency"
0 or "maximum frequency limit" to "maximum fre-
quency"
0 to 40000(100000)
0 to 1000(10000)
0 to 40000(100000)
0 to 1000(10000)
0 to 40000(100000)
0 to 1000(10000)
0 to 40000
0 to 600
Units
Run
Modbus
Default
mode
Register
edit
0.01 [Hz]
121Ah
0.00
121Bh
0.01 [Hz]
121Ch
0.00
121Dh
0.01 [Hz]
121Eh
0.00
121Fh
0.01 [Hz]
1220h
0.00
1221h
0.01 [Hz]
1222h
0.00
1223h
0.01 [Hz]
1224h
0.00
1225h
0.01 [Hz]
1226h
0.00
1227h
0.01 [Hz]
1228h
0.00
1229h
0.01 [Hz]
122Ah
0.00
122Bh
0.01 [Hz]
122Ch
0.00
122Dh
0.01 [Hz]
122Eh
0.00
122Fh
0.01 [Hz]
1230h
0.00
1231h
0.01 [Hz]
1232h
0.00
1233h
0.01 [Hz]
1234h
0.00
1235h
0.01 [Hz]
1238h
6.00
-
1239h
04
123Bh
00
0.1 [%]
123Ch
1.0
0.1 [%]
123Dh
5.0
123Eh
00
1 [%]
123Fh
100
1 [%]
1240h
100
1 [%]
1241h
100
1245h
00
0.01 [Hz]
1246h
0.50
0.1 [sec.]
1247h
0.0
1 [%]
1248h
50
0.1 [sec.]
1249h
0.5
124Ah
01
1 [%]
124Bh
0.1 [sec.]
124Ch
0.0
0.1 [kHz]
124Dh
5.0
0.01 [Hz]
124Fh
0.00
1250h
0.01 [Hz]
1251h
0.00
1252h
0.01 [Hz]
1253h
0.00
1254h
0.01 [Hz]
1255h
0.50
0.01 [Hz]
1256h
0.00
1257h
0.01 [Hz]
1258h
0.50
0.01 [Hz]
1259h
0.00
125Ah
0.01 [Hz]
125Bh
0.50
0.01 [Hz]
125Ch
0.00
125Dh
0.1 [sec.]
125Eh
0.0
0
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysdrive mx2 series