Omron 3G3MX2 Quick Start Manual page 29

Born to drive machines; 200 v class three-phase input 0.1 to 15 kw; 200 v class single-phase input 0.1 to 2.2 kw; 400 v class three-phase input 0.4 to 15 kw
Hide thumbs Also See for 3G3MX2:
Table of Contents

Advertisement

MX2 Quick Start Guide
Option
Terminal
Code
Symbol
40
TL
Torque Limit Selection
41
TRQ1
Torque limit switch 1
42
TRQ2
Torque limit switch 2
44
BOK
Brake confirmation
46
LAC
LAD cancellation
47
PCLR
Pulse counter clear
50
ADD
ADD frequency enable
51
F-TM
Force Terminal Mode
52
ATR
Enable torque command input
53
KHC
Clear watt-hour data
56
MI1
General purpose input (1)
57
MI2
General purpose input (2)
58
MI3
General purpose input (3)
59
MI4
General purpose input (4)
60
MI5
General purpose input (5)
61
MI6
General purpose input (6)
62
MI7
General purpose input (7)
65
AHD
Analog command hold
66
CP1
Multistage-position switch (1)
67
CP2
Multistage-position switch (2)
68
CP3
Multistage-position switch (3)
69
ORL
Limit signal of homing
70
ORG
Trigger signal of homing
73
SPD
Speed/position changeover
77
GS1 *
GS1 input
78
GS2 *
GS2 input
81
485
Start EzCOM
82
PRG
Executing Drive programming
83
HLD
Retain output frequency
84
ROK
Permission of Run command
85
EB
Rotation direction detection
(C007 only)
86
DISP
Display limitation
255
no
No function
All this functions could be assigned to any of the multi-function inputs on parameters C001 to C007, select if the input will be
normally open or normally close and the response time of the input.
26
Input Function Summary Table
Function Name
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
OFF
ON
OFF
ON
Parameter
Parameter name
C001
Input [1] function
C002
Input [2] function
C003
Input [3] function
[GS1 assignable]
C004
Input [4] function
[GS2 assignable]
C005
Input [5] function
[PTC assignable]
C006
Input [6] function
C007
Input [7] function
Description
Setting of b040 is enabled
Max. torque is limited with 200%
Torque limit related parameters of Powering/regen, and FW/RV modes are selected by the
combinations of these inputs.
Brake confirmation signal received
Brake confirmation signal not received
Set ramp times are ignored. Inverter output immediately follows the freq. command.
Accel. and/or decel. is according to the set ramp time
Clear the position deviation data
Maintain the position deviation data
Adds the A145 (add frequency) value to the output frequency
Does not add the A145 value to the output frequency
Force inverter to use input terminals for output frequency and Run command sources
Source of output frequency set by A001 and source of Run command set by A002 is used
Torque control command input is enabled
Torque control command input is disabled
Clear watt-hour data
General purpose input (1) to (7) under Drive programming
Analog command is held
Analog command is not held
Multistage position commands are set according to the combination of these switches.
Limit signal of homing is ON
Starts homing operation
Speed control mode
Position control mode
EN60204-1 related signals: Signal input of "Safe torque off" function.
Starts EzCOM
No execution
Executing Drive program
No execution
Retain the current output frequency
Run command permitted
Forward rotation
Reverse rotation
Only a parameter configured in b038 is shown
All the monitors can be shown
(input ignored)
Description
Select input terminal [1] function
Select input terminal [2] function
Select input terminal [3] function
Select input terminal [4] function
Select input terminal [5] function
Select input terminal [6] function
Select input terminal [7] function
MX2 Quick Start Guide