Alarm Types - Nortel CVX 1800 Hardware Installation Manual

Multi-service access switch
Table of Contents

Advertisement

CVX 1800 Hardware Installation Guide
Connecting Alarms

Alarm Types

The following table lists specific alarm types, severity, and possible causes:
Alarm Type
T1 Alarm
T3 Alarm
HSSI Port Down Critical
Ethernet Port
Down
Fan Down
Power Down
SCC Failover
Link Down
Slot Down
Sonet/SDH
Loss of Signal
Sonet/SDH
Loss of Frame
Sonet/SDH C2
Mismatch
Sonet/SDH S1
New Event
3-4
Severity
Description
Critical
An alarm condition has been detected on the
specified T1 line, or the signal on the T1 line has
been lost.
Critical
An alarm condition has been detected on the
specified T3 line, or the signal on the T3 line has
been lost.
The HSSI port has failed to initialize.
Major
The Ethernet port has failed to initialize.
Major
The cooling fans have stopped.
Major
The external power source has dropped.
Major
The primary SCC has failed, and the secondary SCC
has resumed operation. CVXView generates this
alarm. Although the raising trap is generated on the
CVX 600, it does not recognize this as an alarm
condition. This alarm must be cleared manually on
CVXView (Clear Alarms button).
Minor
The sending protocol entity recognizes a failure in
one of the communication links represented in the
agent's configuration.
Minor
Communication has been lost between the indicated
slot and the SCC.
Major
Transitions are not detected on incoming signals,
therefore, a loss of signal is declared.
Major
An OOF/SEF defect has persisted for a period of 3
milliseconds, therefore, a loss of frame is declared.
Minor
The C2 field value in the received frame does not
match the configured value in the SigLabelExpect
attribute.
Minor
The specified STM-1 is in S1 New Alarm. The S1
field in the received frame contains a new value.
296-1011-200 Rel. 5.0, Doc. Rev. 08.01
(continued)

Advertisement

Table of Contents
loading