Omron E5CN-H Communications Manual page 53

Digital controllers
Hide thumbs Also See for E5CN-H:
Table of Contents

Advertisement

SECTION 3 Communications Data for CompoWay/F and SYSWAY
Variable
Address
Parameter name
type
C1 (81)
0022
MV at Stop
C1 (81)
0023
MV at PV Error
C1 (81)
0024
Manual MV
C1 (81)
0025
SP Ramp Set Value (See note 1.)
C1 (81)
0026
MV Upper Limit (See note 2.)
C1 (81)
0027
MV Lower Limit (See note 2.)
C1 (81)
0028
Move to Protect Level
C1 (81)
0029
Password to Move to Protect Level
C1 (81)
002A
Parameter Mask Enable
C1 (81)
002B
PF Key Protect
C1 (81)
002C
MV Change Rate Limit
C1 (81)
002D
Position Proportional Dead Band
C1 (81)
002E
Open/Close Hysteresis
C1 (81)
002F
Heater Overcurrent Detection 1
C1 (81)
0030
Heater Overcurrent Detection 2
C1 (81)
0031
Extraction of Square Root Low-cut
Point
Note 1:
The parameter for the currently selected bank will be accessed.
Note 2:
The parameter for the currently selected PID set will be accessed. For setup area 1, however, the currently selected PID
set is fixed at PID1.
3-4
Setting (monitor) value
Standard: H'FFFFFFCE to H'0000041A ( − 5.0 to 105.0)
Heating/cooling: H'FFFFFBE6 to H'0000041A ( − 105.0 to 105.0)
Position proportional (Floating or direct setting of position proportional
MV OFF): H'FFFFFFFF to H'00000001 ( − 1 to 1)
Position proportional (Closed and direct setting of position proportional
MV ON): H'FFFFFFCE to H'0000041A ( − 5.0 to 105.0)
Standard: H'FFFFFFCE to H'0000041A ( − 5.0 to 105.0)
Heating/cooling: H'FFFFFBE6 to H'0000041A ( − 105.0 to 105.0)
Position proportional (Floating or direct setting of position proportional
MV OFF): H'FFFFFFFF to H'00000001 ( − 1 to 1)
Position proportional (Closed and direct setting of position proportional
MV ON): H'FFFFFFCE to H'0000041A ( − 5.0 to 105.0)
Standard: H'FFFFFFCE to H'0000041A ( − 5.0 to 105.0)
Heating/cooling: H'FFFFFBE6 to H'0000041A ( − 105.0 to 105.0)
Position proportional (Floating or direct setting of position proportional
MV OFF): H'FFFFFFFF to H'00000001 ( − 1 to 1)
Position proportional (Closed and direct setting of position proportional
MV ON): H'FFFFFFCE to H'0000041A ( − 5.0 to 105.0)
H'00000000(0): OFF
H'00000001 to H'00007E90 (1 to 32400)
Standard: MV lower limit + 0.1 to H'0000041A
(MV lower limit + 0.1 to 105.0)
Heating/cooling: H'00000000 to H'0000041A (0.0 to 105.0)
Position proportional (closed): MV lower limit +0.1 to H'0000041A
(MV lower limit +0.1 to 105.0)
Standard: H'FFFFFFCE to MV upper limit − 0.1
( − 5.0 to MV upper limit − 0.1)
Heating/cooling: H'FFFFFBE6 to H'00000000 ( − 105.0 to 0.0)
Position proportional (closed): H'FFFFFFCE to MV upper limit − 0.1
( − 5.0 to MV upper limit − 0.1)
H'FFFFF831 to H'0000270F ( − 1999 to 9999)
H'FFFFF831 to H'0000270F ( − 1999 to 9999)
(Can only be set. The monitor value is always H'00000000.)
H'00000000 (0): OFF
H'00000001 (1): ON
H'00000000 (0): OFF
H'00000001 (1): ON
H'00000000 to H'000003E8 (0.0 to 100.0)
H'00000001 to H'00000064 (0.1 to 10.0)
H'00000001 to H'000000C8 (0.1 to 20.0)
H'00000000 to H'000001F4 (0.0 to 50.0)
H'00000000 to H'000001F4 (0.0 to 50.0)
H'00000000 to H'000003E8 (0.0 to 100.0)
Level
Adjustment
Manual
Control
Adjustment
Protect
Adjustment

Advertisement