Omron E5CN-H Communications Manual page 114

Digital controllers
Hide thumbs Also See for E5CN-H:
Table of Contents

Advertisement

Address
Parameter name
Four-byte
Two-byte
mode
mode
1400
3400
Bank 0 SP
1402
3401
Bank 0 PID Set No.
1404
3402
Bank 0 SP Ramp Set Value
1406
3403
Bank 0 Alarm Value 1
Bank 0 Alarm Value Upper Limit 1 H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
1408
3404
Bank 0 Alarm Value Lower Limit 1 H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
140A
3405
140C
3406
Bank 0 Alarm Value 2
Bank 0 Alarm Value Upper Limit 2 H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
140E
3407
Bank 0 Alarm Value Lower Limit 2 H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
1410
3408
1412
3409
Bank 0 Alarm Value 3
Bank 0 Alarm Value Upper Limit 3 H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
1414
340A
Bank 0 Alarm Value Lower Limit 3 H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
1416
340B
141A
340D
Bank 0 Soak Time
141C
340E
Bank 0 Wait Band
1420
3410
Bank 1 SP
to
143C
341E
Bank 1 Wait Band
1440
3420
Bank 2 SP
to
145C
342E
Bank 2 Wait Band
1460
3430
Bank 3 SP
to
147C
343E
Bank 3 Wait Band
1480
3440
Bank 4 SP
to
149C
344E
Bank 4 Wait Band
14A0
3450
Bank 5 SP
to
14BC
345E
Bank 5 Wait Band
14C0
3460
Bank 6 SP
to
14DC
346E
Bank 6 Wait Band
14E0
3470
Bank 7 SP
to
14FC
347E
Bank 7 Wait Band
6.1 Variable Area (Setting Range) List
Setting (monitor) value
SP lower limit to SP upper limit
H'00000000 to H'00000008 (0 to 8) (0: Auto selection)
H'00000000 (0): OFF
H'00000001 to H'00007E90 (1 to 32400)
H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
H'00000001 to H'0000270F (1 to 9999)
H'00000000 (0): OFF
Temperature: H'00000001 to H'00007E90 (0.1 to 3240.0)
Analog: H'00000001 to H'0000270F (0.01 to 99.99)
SP lower limit to SP upper limit
H'00000000 (0): OFF
Temperature: H'00000001 to H'00007E90 (0.1 to 3240.0)
Analog: H'00000001 to H'0000270F (0.01 to 99.99)
SP lower limit to SP upper limit
H'00000000 (0): OFF
Temperature: H'00000001 to H'00007E90 (0.1 to 3240.0)
Analog: H'00000001 to H'0000270F (0.01 to 99.99)
SP lower limit to SP upper limit
H'00000000 (0): OFF
Temperature: H'00000001 to H'00007E90 (0.1 to 3240.0)
Analog: H'00000001 to H'0000270F (0.01 to 99.99)
SP lower limit to SP upper limit
H'00000000 (0): OFF
Temperature: H'00000001 to H'00007E90 (0.1 to 3240.0)
Analog: H'00000001 to H'0000270F (0.01 to 99.99)
SP lower limit to SP upper limit
H'00000000 (0): OFF
Temperature: H'00000001 to H'00007E90 (0.1 to 3240.0)
Analog: H'00000001 to H'0000270F (0.01 to 99.99)
SP lower limit to SP upper limit
H'00000000 (0): OFF
Temperature: H'00000001 to H'00007E90 (0.1 to 3240.0)
Analog: H'00000001 to H'0000270F (0.01 to 99.99)
SP lower limit to SP upper limit
H'00000000 (0): OFF
Temperature: H'00000001 to H'00007E90 (0.1 to 3240.0)
Analog: H'00000001 to H'0000270F (0.01 to 99.99)
Level
Bank
setting
6-13

Advertisement