SECTION 6 Communications Data for Modbus
Address
Four-
Two-
Parameter name
byte
byte
mode
mode
0722
2711
MV at PV Error
0726
2713
MV Change Rate Limit
072C
2716
Lower Limit Temperature Input Shift Value
0730
2718
Upper Limit Temperature Input Shift Value
0734
271A
Heater Current 1 Value Monitor
0736
271B
Heater Burnout Detection 1
0738
271C
Leakage Current 1 Monitor
073A
271D
HS Alarm 1
0746
2723
Temperature Input Shift
0748
2724
Heater Current 2 Value Monitor
074A
2725
Heater Burnout Detection 2
074C
2726
Leakage Current 2 Monitor
074E
2727
HS Alarm 2
0750
2728
Soak Time Remain
0752
2729
Soak Time (See note 1.)
0754
272A
Wait Band (See note 1.)
0756
272B
Heater Overcurrent Detection 1
0758
272C
Heater Overcurrent Detection 2
0800
2800
Input Digital Filter
0810
2808
Extraction of Square Root Low-cut Point
0904
2902
Alarm Value 1 (See note 1.)
0906
2903
Alarm Value Upper Limit 1 (See note 1.)
0908
2904
Alarm Value Lower Limit 1 (See note 1.)
090A
2905
Alarm Value 2 (See note 1.)
090C
2906
Alarm Value Upper Limit 2 (See note 1.)
090E
2907
Alarm Value Lower Limit 2 (See note 1.)
0910
2908
Alarm Value 3 (See notes 1 and 2.)
Alarm Value Upper Limit 3 (See notes 1 and 2.) H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
0912
2909
Alarm Value Lower Limit 3 (See notes 1 and 2.) H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
0914
290A
0A00
2A00
Proportional Band (See note 3.)
0A02
2A01
Integral Time (See note 3.)
0A04
2A02
Derivative Time (See note 3.)
0A0A
2A05
MV Upper Limit (See note 3.)
Note:
The alarm function can also be used in Controllers without alarm output terminals. In this case, confirm alarm occurrences via the
status data.
Note 1:
The parameter for the currently selected bank will be accessed.
Note 2:
Not displayed on the Controller display when Alarm 3 is not assigned to an output.
Note 3:
The parameter for the currently selected PID set will be accessed. For setup area 1, however, the currently selected PID set is fixed at
PID1.
6-4
Setting (monitor) value
Standard: H'FFFFFFCE to H'0000041A ( − 5.0 to 105.0)
Heating/cooling: H'FFFFFBE6 to H'0000041A ( − 105.0 to 105.0)
Position proportional (Floating or direct setting of position propor-
tional MV OFF): H'FFFFFFFF to H'00000001 ( − 1 to 1)
Position proportional (Closed and direct setting of position propor-
tional MV ON): H'FFFFFFCE to H'0000041A ( − 5.0 to 105.0)
H'00000000 to H'000003E8 (0.0 to 100.0)
H'FFFFB1E1 to H'00007E90 ( − 199.99 to 324.00)
H'FFFFB1E1 to H'00007E90 ( − 199.99 to 324.00)
H'00000000 to H'00000226 (0.0 to 55.0)
H'00000000 to H'000001F4 (0.0 to 50.0)
H'00000000 to H'00000226 (0.0 to 55.0)
H'00000000 to H'000001F4 (0.0 to 50.0)
H'FFFFB1E1 to H'00007E90 ( − 199.99 to 324.00)
H'00000000 to H'00000226 (0.0 to 55.0)
H'00000000 to H'000001F4 (0.0 to 50.0)
H'00000000 to H'00000226 (0.0 to 55.0)
H'00000000 to H'000001F4 (0.0 to 50.0)
H'00000000 to H'0000270F (0 to 9999)
H'00000000 to H'0000270F (0 to 9999)
H'00000000 (0): OFF
Temperature: H'00000001 to H'00007E90 (0.1 to 3240.0)
Analog: H'00000001 to H'0000270F (0.01 to 99.99)
H'00000000 to H'000001F4 (0.0 to 50.0)
H'00000000 to H'000001F4 (0.0 to 50.0)
H'00000000 to H'0000270F (0.0 to 999.9)
H'00000000 to H'000003E8 (0.0 to 100.0)
H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
H'FFFFB1E1 to H'00007E90 ( − 19999 to 32400)
Temperature: H'00000001 to H'00007E90 (0.1 to 3240.0)
Analog: H'00000001 to H'0000270F (0.1 to 999.9)
Standard, heating/cooling, position proportional (closed):
H'00000000 to H'00007E90 (0.0 to 3240.0)
Position proportional (floating): H'00000001 to H'00007E90
(0.1 to 3240.0)
H'00000000 to H'00007E90 (0.0 to 3240.0)
Standard: MV lower limit +0.1 to H'0000041A
(MV lower limit +0.1 to 105.0)
Heating/cooling: H'00000000 to H'0000041A (0.0 to 105.0)
Position proportional (closed): MV lower limit +0.1 to H'0000041A)
MV lower limit +0.1 to 105.0)
Level
Adjustment
Operation
Adjustment
Operation
Adjustment
Operation
Adjustment
Operation
Adjustment
Operation
Adjustment
Advanced
function
setting
Adjustment
Operation
Adjustment

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5en-hE5an-h

Table of Contents