4-3.2 Change Definition Command 40H; 4-3.2.1 Change Definition Cdb Description; Table 4-3. Change Definition Field Description - Fujitsu M2488 Product Manual

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

M2488 PRODUCT GUIDE
4-3.2
CHANGE DEFINITION command 40h
The CHANGE DEFINITION command is used to modify the operating definition of the selected tar-
get with respect to all initiators. This command is executed even if the Magnetic Tape Unit (MTU) is
NOT READY. It is not executed if the selected LUN is nonexistent. This command is used in con-
junction with the INQUIRY command to change (and optionally save) parameters that affect the
operation of the target.
4-3.2.1
CHANGE DEFINITION CDB Description
CHANGE DEFINITION is a ten-byte command. The bytes are shown below and described in
Table 4-3. Common fields are described in paragraph 4-3.1 on page 4-4.
BYTES
7
0
0
1
2
3
0
4
5
6
7
8
9
Note: Changeable fields in the CDB are shaded.

Table 4-3. CHANGE DEFINITION Field Description

BYTE
BIT
VALUE
0
0-7
40h
2
0
0
1
3
0-6
April 1997
6
5
4
1
0
0
LUN
Reserved
Parameter Data Length
Reserved
Operation code.
A Save control bit of zero indicates that the target shall not save the operating definition.
A Save bit of one indicates that the target shall save the operating definition to non-volatile
memory.
This target will not apply the new parameters until a power cycle is performed, so sending
a Save bit of zero is a means of performing a parameter validity check.
See Table 4-4 for a description of the Definition Parameter field.
CG00000-011503 REV. A
TAPE UNIT SCSI COMMANDS
BITS
3
2
0
0
Reserved
Definition Parameters
Reserved
DESCRIPTION
1
0
0
0
Save
Flag
Link
4-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents