4-3.15.2 Read Block Limits Sense Keys - Fujitsu M2488 Product Manual

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

M2488 PRODUCT GUIDE
If a DMA transfer (READ, WRITE, READ BUFFER, WRITE BUFFER, OR LOOP WRITE TO
READ) is requested by the host with a transfer length of zero bytes, this is not considered an error.
The command is processed with no data transfer. There is no block ID associated with zero length
records.
4-3.15.2
READ BLOCK LIMITS Sense Keys
One of the following sense keys may be returned if a CHECK CONDITION was indicated:
SENSE KEY
CONDITION
1h
RECOVERED ERROR
3h
MEDIUM ERROR
4h
HARDWARE ERROR
5h
ILLEGAL REQUEST
6h
UNIT ATTENTION
April 1997
Recovery was performed when writing buffered data.
1. Write of buffered data failed due to defective tape.
2. An attempt was made to write 36-track data on 18-track format-
ted medium.
Write of buffered failed due to a hardware error.
1. Reserved bit was set in the CDB of the READ BLOCK LIM-
ITS command
2. Flag bit was set and Link bit was not set.
Indicates the READ BLOCK LIMITS command was not per-
formed due to one of the following:
1. The tape cartridge may have been changed.
2. The target has been reset.
3. The Mode parameters have been changed by another initiator.
4. The version of the microcode has been changed (microcode
downloaded).
5. A cartridge was loaded with a tape length that is too long or too
short.
CG00000-011503 REV. A
TAPE UNIT SCSI COMMANDS
DESCRIPTION
4-69

Hide quick links: