Theory of Operation
2-24
Developing Voltage (DEV)
The Developing Voltage is supplied to the Developer Roller to transfer to the
toner to the charge on the OPC Drum scanned by the laser beam while
printing the image. The engine controls whether the high voltage is supplied
and its quantity.
Input voltage: 24 VDC ± 15%
Output voltage: -200 V ~ 600 V DC ± 3%
Output voltage fluctuation method: PWM control
Line regulation: under ± 3% (fluctuation input 21.6 V~27.6 V)
Load regulation: under ± 3%
Output voltage rising time: 50 ms Max
Output voltage falling time: 50 ms Max
Output Control Signal (BIAS-PWM): The CPU output is HV output when
PWM is low.
Supply
Output voltage: -300 V~800 VDC ± 50 V (ZENER using, DEV)
Line regulation: under ± 3% (fluctuation input 21.6 V~27.6 V)
Load regulation: under ± 3%
Output voltage rising time: 50 ms Max
Output voltage falling time: 50 ms Max
Output control signal (BIAS-PWM): The CPU is HV output when PWM is
Low.
WorkCentre 3210/3220 Multifunction Printer Service Manual