Removal Of The Pcb / Electrical Box - Daikin B-Series Service Manual

Inverter pair wall mounted type
Hide thumbs Also See for B-Series:
Table of Contents

Advertisement

Outdoor Unit
2.3
Removal of the
Procedure
Step
Remove the top panel
and the front panel.
1. Remove the right side
panel.
Disconnect the three
1
connection wirings and
the two
earth
wires.
2
Loosen the three
screws of the
right side
panel.
3
Loosen the fixing screw
of the electrical box.
178
PCB
/
Electrical Box
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Si04-306E
Points
Terminal strip
number
black (1) ----- power supply
white (2) ----- power supply
red (3) ----- transmission
yellow / green (
) ----- earth