Outdoor Unit
2.4
Removal of the Reactor
Procedure
Step
Remove the electrical box.
1. Remove the
partition
plate.
Release the clamp by
1
pliers.
2
Loosen the two screws
of the partition plate.
186
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Claw
The partition plate is fixed to
the bottom frame with a
claw.
(R2724)
Si04-306E
Points
Removal Procedure