Si04-306E
Step
3. Remove the fan motor.
Remove the
fan
motor.
1
4. Remove the bearing.
1
Remove the
fan
rotor.
The bearing is on the
left side.
2
Loosen the two screws
and remove the
mounting plate for the
bearing.
The bearing is made of
3
rubber. Push it inwards
firmly and remove it.
Removal Procedure
Procedure
Indoor Unit
Points
Reassembling the fan motor
(1) When reassembling the fan
rotor, provide as much as
5mm of play between the
side face of the rotor and the
bottom frame.
Side face of
Side face of rotor
bottom frame
5mm
(2) When reassembling the fan
motor, align the end of the
connector with the height of
for play.
(R2808)