Specifications
Indoor Units
Model
Outdoor Units
Capacity
Rated (Min.~Max.)
Moisture Removal
Running Current (Rated)
Power Consumption
Rated (Min.~Max.)
Power Factor
COP (Rated)
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of
Refrigerant
Indoor Unit
Front Panel Color
m³/min
Airflow Rate
(cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current
Power Consumption
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Outdoor Unit
Casing Color
Type
Compressor
Model
Motor Output
Type
Refrigerant Oil
Charge
Type
Refrigerant
Charge
Airflow Rate
m³/min (cfm)
Type
Fan
Motor Output
Running Current
Power Consumption
Power Factor
Starting Current
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/L
Sound
Drawing No.
Note:
22
FTKD18BVMS
RKD18BVMS
kW
5.2 (0.9~5.8)
Btu/h
17,700 (3,070~19,800)
kcal/h
4,470 (770~4,990)
L/h
2.9
A
6.9
W
1,500 (450~2,300)
%
98.8
W/W
3.47
φ
mm
6.4
φ
mm
15.9
φ
mm
18.0
Both Liquid and Gas Pipes
m
30
m
20
m
10
g/m
20
FTKD18BVMS
White
H
17.4 (614)
M
14.6 (515)
L
12.2 (431)
SL
10. 8 (381)
Cross Flow Fan
W
43
Steps
5 Steps, Quiet and Auto
Right, Left, Horizontal and Downward
Removable/Washable/Mildew Proof
A
0.21
W
45
%
97.4
Microcomputer Control
mm
290×1,050×238
mm
337×1,147×366
kg
12
kg
17
dBA
45/41/36/33
RKD18BVMS
Ivory White
Hermetically Sealed Swing Type
2YC32UXD
W
1,500
SE50P
L
0.65
R-22
kg
1.60
H
46.3 (1,634)
L
42.9 (1,514)
Propeller
W
53
A
6.69
W
1,455
%
98.9
A
6.9
mm
735×825×300
mm
784×960×390
kg
52
kg
57
dBA
49/46
3D040821
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
FTKD24BVMS
RKD24BVMS
6.1 (0.9~7.0)
20,800 (3,070~23,900)
5,250 (770~6,020)
3.9
8.5
1,850 (450~2,900)
98.9
3.30
φ
9.5
φ
15.9
φ
18.0
Both Liquid and Gas Pipes
30
20
10
50
FTKD24BVMS
White
17.9 (632)
15.0 (530)
12.4 (438)
11.0 (388)
Cross Flow Fan
43
5 Steps, Quiet and Auto
Right, Left, Horizontal and Downward
Removable/Washable/Mildew Proof
0.23
50
98.8
Microcomputer Control
290×1,050×238
337×1,147×366
12
17
46/42/37/34
RKD24BVMS
Ivory White
Hermetically Sealed Swing Type
2YC45ZXD
1,900
SUNISO 4GSD.I.
0.75
R-22
1.70
51.5 (1,818)
41.5 (1,465)
Propeller
53
8.27
1,800
98.9
8.5
735×825×300
784×960×390
54
59
52/49
3D040822
Piping Length
7.5m
Si04-306E
50Hz 220V
FTKD28BVMS
RKD28BVMS
7.5 (0.9~7.8)
25,600 (3,070~26,600)
6,450 (775~6,710)
4.5
13.7
2,970 (450~3,270)
98.5
2.53
φ
9.5
φ
15.9
φ
18.0
Both Liquid and Gas Pipes
30
20
10
50
FTKD28BVMS
White
19.0 (671)
15.9 (561)
13.1 (462)
11.8 (417)
Cross Flow Fan
43
5 Steps, Quiet and Auto
Right, Left, Horizontal and Downward
Removable/Washable/Mildew Proof
0.24
52
98.5
Microcomputer Control
290×1,050×238
337×1,147×366
12
17
47/43/38/35
RKD28BVMS
Ivory White
Hermetically Sealed Swing Type
2YC63ZXD
1,900
SUNISO 4GSD.I.
0.65
R-22
1.80
56.0 (1,977)
44.5 (1,571)
Propeller
53
13.46
2,918
98.5
13.7
735×825×300
784×960×390
56
61
52/49
3D042234
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Specifications

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents