Daikin B-Series Service Manual page 219

Inverter pair wall mounted type
Hide thumbs Also See for B-Series:
Table of Contents

Advertisement

Wiring Diagrams
FT(Y)S50BVMB
PCB3
S27
S26
R1T
S38
PCB4
S37
S21
LED1
LED2
H1P
H2P
PCB2
SIGNAL
RECEIVER
WIRELESS
S1W
REMOTE
CONTROLLER
FT(Y)S60BVMB
PCB3
S27
S26
R1T
S38
PCB4
S37
S21
LED1
LED2
H1P
H2P
PCB2
SIGNAL
RECEIVER
WIRELESS
S1W
REMOTE
CONTROLLER
208
PCB1
~
~
RECTIFIER
TRANSMISSION
CIRCUIT
S28
S32
1
S6
5
S29
R2T
M
M1S
PCB1
~
~
RECTIFIER
TRANSMISSION
S28
S32
1
S6
5
S29
R2T
M
M1S
H1
Fu
3.15A
H2
GRN
H3
FG
S1
7
RED
BLU
BRN
M
ORG
WHT
1
M1F
INDOOR
H1
Fu
3.15A
H2
GRN
H3
CIRCUIT
FG
S1
7
RED
M
BLU
BRN
ORG
M1F
1
WHT
INDOOR
FIELD WIRING.
X1M
1
BLK
WHT
2
RED
3
/
YLW
CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
FG
: FRAME GROUND
Fu
: FUSE
H1~H3
: HARNESS
H1P~H2P
: PILOT LAMP
M1F
: FAN MOTOR
M1S
: SWING MOTOR
PCB1~PCB4
: PRINTED CIRCUIT BOARD
R1T, R2T
: THERMISTOR
S1~S38
: CONNECTOR
S1W
: OPERATION SWITCH
X1M
: TERMINAL STRIP
: PROTECTIVE EARTH
FIELD WIRING.
X1M
1
BLK
2
WHT
3
RED
CAUTION
/
YLW
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
FG
: FRAME GROUND
Fu
: FUSE
H1~H3
: HARNESS
H1P~H2P
: PILOT LAMP
M1F
: FAN MOTOR
M1S
: SWING MOTOR
PCB1~PCB4
: PRINTED CIRCUIT BOARD
R1T, R2T
: THERMISTOR
S1~S38
: CONNECTOR
S1W
: OPERATION SWITCH
X1M
: TERMINAL STRIP
: PROTECTIVE EARTH
Si04-306E
1
2
3
OUTDOOR
3D038466C
1
2
3
OUTDOOR
3D038532F