Daikin B-Series Service Manual page 191

Inverter pair wall mounted type
Hide thumbs Also See for B-Series:
Table of Contents

Advertisement

Outdoor Unit
Step
2
Push the claw up to
release the cable way
board.
Open the cable way
board.
3
Disconnect the
harnesses from the
power supply PCB.
HL
(black) ···· to the
terminal strip
HE2
(yellow / green) ····
to the terminal strip
(earth)
HAC1
(black) ···· from
the control PCB (AC1)
HE1
(yellow / green) ····
from the control PCB
(E)
4
Disconnect the
connectors of the front
side.
S20: electronic
expansion valve
S40: overload protector
S80: four way valve
S90: thermistors
(discharge pipe,
outdoor air,
heat exchanger)
180
Procedure
Si04-306E
Points
Power supply PCB
HE1
V3(varistor)
HAC1
HE2
HL
FU1 250V 30A
(soldered)
(R2707)
Removal Procedure

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents