Configuring Domain Parameters

Displaying Pending Changes

You can display the pending configuration changes using the show fcdomain pending command.
switch# show fcdomain pending vsan 10
Pending Configured Allowed Domains
----------------------------------
VSAN 10
Assigned or unallowed domain IDs: 1-9,24,100,231-239.
[User] configured allowed domain IDs: 10-230.
You can display the differences between the pending configuration and the current configuration using the
show fcdomain pending-diff command.
switch# show fcdomain pending-diff vsan 10
Current Configured Allowed Domains
----------------------------------
VSAN 10
Assigned or unallowed domain IDs: 24,100.
[User] configured allowed domain IDs: 1-239.
Pending Configured Allowed Domains
----------------------------------
VSAN 10
Assigned or unallowed domain IDs: 1-9,24,100,231-239.
[User] configured allowed domain IDs: 10-230.

Displaying Session Status

You can display the status of the distribution session using the show fcdomain session-status vsan command.
switch# show fcdomain session-status vsan 1
Last Action: Distribution Enable
Result: Success

About Contiguous Domain ID Assignments

By default, the contiguous domain assignment is disabled. When a subordinate switch requests the principal
switch for two or more domains and the domains are not contiguous, the following situations can occur:
• If the contiguous domain assignment is enabled in the principal switch, the principal switch locates
• If the contiguous domain assignment is disabled in the principal switch, the principal switch assigns the

Enabling Contiguous Domain ID Assignments

To enable contiguous domains in a specific VSAN (or a range of VSANs), perform this task:
SUMMARY STEPS
1. switch# configuration terminal
2. switch(config)# fcdomain contiguous-allocation vsan vsan-id - vsan-id
3. switch(config)# no fcdomain contiguous-allocation vsan vsan-id
OL-xxxxx-xx
contiguous domains and assigns them to the subordinate switches. If contiguous domains are not available,
the switch software rejects this request.
available domains to the subordinate switch.