Configuring NPV
Command or Action
Step 3
switch(config-if)# switchport mode F
Step 4
switch(config-if)# no shutdown
Configuring NPV Traffic Management
Configuring NPV Traffic Maps
An NPV traffic map associates one or more NP uplink interfaces with a server interface. The switch associates
the server interface with one of these NP uplinks.
If a server interface is already mapped to an NP uplink, you should include this mapping in the traffic
Note
map configuration.
To configure a traffic map, perform this task:
SUMMARY STEPS
1. switch# config t
2. switch(config)# npv traffic-map server-interface {fc slot/port | vfc vfc-id} external-interface fc slot/port
3. switch(config)# no npv traffic-map server-interface {fc slot/port | vfc vfc-id} external-interface fc
slot/port
DETAILED STEPS
Command or Action
Step 1
switch# config t
Step 2
switch(config)# npv traffic-map server-interface {fc
slot/port | vfc vfc-id} external-interface fc slot/port
Step 3
switch(config)# no npv traffic-map server-interface
{fc slot/port | vfc vfc-id} external-interface fc slot/port
Enabling Disruptive Load Balancing
If you configure additional NP uplinks, you can enable the disruptive load-balancing feature to distribute the
server traffic load evenly among all the NP uplinks.
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide
56
Purpose
Configures the interface as an F port.
Brings up the interface.
Purpose
Enters configuration mode on the NPV.
Configures a mapping between a server interface (or range
of server interfaces) and an NP uplink interface (or range
of NP uplink interfaces).
Removes the mapping between the specified server
interfaces and NP uplink interfaces.
Configuring N Port Virtualization
OL-xxxxx-xx