2. PREVENTIVE MAINTENANCE
2.1 PM TABLE
Key for the PM Table
Letter
Action
A
Adjust
C
Clean
I
Inspect
L
Lubricate
R
Replace
NOTE: Units of measure in the PM Interval column*:
Metric: 1,000 meters, Feet: 1,000 feet, Prints: 1,000 prints/A1 LEF or D
2.1.1 COPIER (B125)
Description
Original Feed Rollers
Original Exit Rollers
Platen Plate
Original Width, Set,
Registration, Exit Sensors
Original Table
Exposure Glass
CIS Surfaces
Development
Developer
Development Filter
Development Roller Gear
Development Lower Casing
Cleaning
Cleaning Blade
Cleaning Entrance Seal
Side Seals
Inside Cleaning Unit
Used Toner Bottle
Registration
Registration Rollers
Paper Registration Sensor
.
SM
PM Interval
Q'ty
Metric
Feet
5.5
18.0
5.5
18.0
5.5
18.0
33.0
108.0
5.5
18.0
5.5
18.0
5.5
18.0
2
27.5
90.0
5.5
18.0
5.5
18.0
5.5
18.0
11.0
36.0
1
11.0
36.0
11.0
36.0
11.0
36.0
5.5
18.0
5.5
18.0
5.5
18.0
2-1
PM
Comments
Prints
Alcohol or damp cloth
9.3
C
9.3
C
9.3
C
Blower brush
55.8
C
9.3
C
Dry cloth
9.3
Damp cloth or glass
C
cleaner
Alcohol or lens paper
9.3
C
46.5
R
Replace if necessary.
Dry cloth or vacuum
9.3
C
cleaner
9.3
I
9.3
C
Dry cloth.
18.6
Replace if necessary.
I/R
18.6
C
Lens paper or dry
cloth.
18.6
C
Dry cloth or vacuum
18.6
I
cleaner
Empty used toner
9.3
C
9.3
C
Alcohol with cloth
Blower brush
9.3
C
PM TABLE