P62, P80, And P82 Series Consoles - Precor TRM700-16 Base Service Manual

Experience series 700 line
Hide thumbs Also See for TRM700-16 Base:
Table of Contents

Advertisement

DIAGNOSTIC
TEST
STOP KEY TEST

P62, P80, and P82 Series Consoles

Menu path: Hardware Validation Tests (5,1,7,6,5,7,6,1) > System Settings > System
Tests.
On P62, P80, and P82 consoles, the diagnostic tests are located in the Hardware Validation
System Tests menu.
SYSTEM TESTS
AUTO STOP
TEST
BELT SPEED
TEST
1
Upper PCA board
2
Lower PCA board
Experience Series 700 Line Treadmills
• SEC - UP/DWN command response delay between the
2
LPCA
.
• Glitches - Momentary failures in the A/D potentiometer output. If there are
more than 50 Glitches, the lift motor should be replaced.
.
Menu path: MACHINE TEST > STOP KEY TEST
(P10, P30 consoles only)
Verifies the Stop Key and E-Stop function
Test sequence steps;
1.  StopKey test - Press the Stop Key
2.  Lanyard ESTOP test- Pull the lanyard to trip the emergency stop function.
3.  Exit test - Press the Stop button to reset and exit test.
Menu path: MACHINE TEST > AUTO STOP TEST
Test parameters;
• Status - User detected on running belt (detected/not detected)
• Step Count - Average # of footplants. Footplant averaging delay reset with
each speed change.
Menu path: MACHINE TEST > BELT SPEED TEST
Tests belt operating condition in 0.1 speed increments
Test parameters:
• AMPS IN: Treadmill input Current.
• VOLTS IN: Treadmill input Voltage
• VBUSS: Treadmill internal buss Voltage
Hardware Validation Service Mode (51765761)
TEST DESCRIPTION
TEST DESCRIPTION
3 Standard Service Modes
1
UPCA
and
23