How to Remove the Foot Pump
Component damage hazard.
The work area and surfaces
where this procedure will be
performed must be clean and
free of debris that could get into
the hydraulic system.
1
Pull the base lowering handle to fully lower the
base.
2
Remove the linkage mounting fasteners from
the foot pump.
3
Remove the foot pump from the manifold. Plug
the port in the manifold.
Note: The foot pump must be bled after installation.
How to Bleed the Foot Pump
1
Pull the base lowering handle to fully lower the
base.
2
Place a container under the base lowering
cylinder, and remove the bleed screw from the
barrel-end of the base lowering cylinder.
3
Pump the foot pedal until air stops coming out
of the bleed screw hole.
4
While holding the foot pedal down, install the
bleed screw.
5
Release the foot pedal.
6
Check the sight gauge on the side of the
hydraulic tank.
7
Add oil if needed. Do not overfill.
8
Clean up any oil that may have spilled.
Properly discard the used oil.