How to Adjust the Base Release
Cable
1
Pull the base lowering handle to fully lower the
base.
2
Remove the cover from the base manifold.
3
Be sure the cable is properly connected to the
manual valve at the base manifold.
1 lock nut
2 coupler
3 base release cable
4 cable mounting bracket
4
Be sure the cable is attached to the cable
mounting bracket with a lock nut on each side.
There should be ¼ to ½ inch / 6.35 to 12.7 mm
of threads on the manifold side of the bracket.
Part No. 38139
5
6
AWP Super Series • IWP Super Series
Base Assembly
Locate the base release cable mounting
bracket on the bottom side of the number 1
column.
1 number 1 column
2 base release cable
3 cable striker bracket
4 slider bracket
5 spring
6 lock nut
7 cable mounting bracket
Loosen the mounting fasteners on the cable
mounting bracket and the cable striker bracket
on the number 1 column. Do not remove the
fasteners.
Service Manual
67