Checklist A Procedures
3
Check the interlock display lights at the ground
controls.
Result: Confirm that the corresponding light is
on.
4
Repeat steps 2 and 3 for each of the
remaining outriggers.
IWPS models
1
Turn the key switch to ground control and pull
out the red Emergency Stop button to the
position. Twist to release the red Emergency
Stop button at the platform controls.
Result: The power light should be on.
2
Pull the base lowering handle to fully lower the
base.
3
Use the bubble level and adjust the leveling
jacks until the machine is level and all four foot
pads are in firm contact with the ground.
Result: Within 1 to 3 seconds, all four interlock
display lights should turn on and remain on.
4
Pump the foot pedal to raise the base.
Result: Both foot pad interlock display lights
should be off.
42
5
6
7
8
9
10 Push in the control activate button and rotate
ON
AWP Super Series • IWP Super Series
Pull the base lowering handle to fully lower the
base.
Result: The base will lower and both foot pad
interlock display lights should be on.
Pump the foot pedal to raise the base.
Turn both leveling jacks clockwise to the
full/extended position.
Pull the base lowering handle to fully lower the
base.
Result: The base will lower and the two level
sensor interlock display lights should be off
and remain off.
Push in the red Emergency Stop button at the
platform controls.
the up/down switch in the up position, then the
down position.
Result: Platform up/down functions should not
operate.