Genie AWP Super Series Service Manual page 58

Hide thumbs Also See for AWP Super Series:
Table of Contents

Advertisement

Service Manual
Checklist C Procedures
4
Loosen but do not remove the adjustment nut
on the sequencing cable located at the top of
the first column.
5
Raise the platform approximately 3 feet / 1 m
above the top of the base.
6
Place a jack stand on the top of the base,
centered under the platform. Adjust the jack
stand to 24 inches / 61 cm.
7
Lower the platform onto the jack stand just
enough to take the weight off the lifting chains.
Crushing hazard. Keep away
from lowering platform.
58
8
Note: If idler wheel inspection results in a
measurement that is not within specification,
replace the idler spacers. Refer to Repair
Procedure, How to Assemble the Mast.
9
10 Install the mast covers and adjust the
AWP Super Series • IWP Super Series
Inspect each idler wheel for the following:
• Excessive wear on the side flanges
• Unusual wear
• Movement side to side in excess of 0.079
inch / 2 mm
• Any movement of wheel front to back
1 Chain
2 Idler Wheel
3 Spacer
Raise the platform and remove the jack stand
and the support blocks. Then lower the
platform.
sequencing cable. Refer to Maintenance
Procedure, Adjust the Sequencing Cables.
September 2016
Part No. 38139

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iwp super series

Table of Contents