Checklist C Procedures
5
Remove the tank from the hydraulic power
unit.
6
Remove the suction strainer from the pick-up
tube and the magnet from inside the tank and
clean them using a mild solvent.
7
Install the suction strainer.
8
Install the drain plug using thread sealer on
the threads.
9
Install the hydraulic tank.
10 Fill the tank with hydraulic oil until the level is
visible in the sight gauge on the side of the
tank. Do not overfill.
11 Replace the breather cap with a new one.
12 Raise and lower the platform through three
complete cycles. Add hydraulic oil if needed to
allow platform to reach full height.
13 Clean up any oil that may have spilled.
Properly discard the used oil.
Component damage hazard. Do
not allow the hydraulic tank to
completely empty when raising
the platform. Pressurized air in
the hydraulic system can
damage hydraulic components.
60
Hydraulic System
Hydraulic fluid
Hydraulic tank capacity - all
models
Hydraulic System Capacity (includes tank)
IWP AC and DC models
IWP-20S
IWP-25S
IWP-30S
AWP AC, DC and Air
Powered models
AWP-15S
AWP-20S
AWP-25S
AWP-30S
AWP-36S
AWP-40S
AWP Super Series • IWP Super Series
September 2016
Chevron Rando HD
equivalent
3 quarts
2.8 liters
3.7 quarts
3.5 liters
3.7 quarts
3.5 liters
3.7 quarts
3.5 liters
3.7 quarts
3.5 liters
3.7 quarts
3.5 liters
3.7 quarts
3.5 liters
3.7 quarts
3.5 liters
4 quarts
3.8 liters
3.9 quarts
3.7 liters
Part No. 38139