APPENDIX
Number
Name
Meaning
SD1300
SD1301
SD1302
SD1303
SD1304
Bit pattern in units of
SD1305
16 points, indicating
SD1306
Fuse blown
the modules whose
fuses have blown
module
SD1307
0: No blown fuse
SD1308
1: Blown fuse present
SD1309
to
SD1330
SD1331
Bit pattern in units of
16 points, indicating
the modules whose
External
external power supply
power
has been
SD1350
supply
disconnected
to
disconnecte
0: External power
SD1381
d module
supply
(For future
disconnected
expansion)
1: External power
supply is not
disconnected
Number
Name
Meaning
SD1400
SD1401
SD1402
SD1403
Bit pattern, in units of
16 points, indicating
SD1404
the modules with
SD1405
I/O module
verification errors.
SD1406
verification
0: No I/O verification
SD1407
error
errors
SD1408
1: I/O verification error
SD1409
present
to
SD1430
SD1431
App - 41
(4) Fuse blown module
• The numbers of output modules whose fuses have blown are
input as a bit pattern (in units of 16 points).
(If the module numbers are set by parameter, the parameter-set
numbers are stored.)
• Also detects blown fuse condition at remote station output
modules
15 14 13 12 11 10 9
0
0
0
SD1300
(YC0)
1
0
0
SD1301
(Y1F0)
0
0
0
SD1331
• Not cleared even if the blown fuse is replaced with a new one.
This flag is cleared by error resetting operation.
The module number (in units of 16 points) whose external power
supply has been disconnected is input as a bit pattern.
(If the module numbers are set by parameter, the parameter-set
numbers are used.)
15 14 13 12 11 10 9
SD1350
0
0
0
0
0
SD1351
1
SD1381
0
0
0
(5) I/O module verification
• When the power is turned on, the module numbers of the I/O
modules whose information differs from the registered I/O
module information are set in this register (in units of 16 points).
(If the I/O numbers are set by parameter, the parameter-set
numbers are stored.)
• Also detects I/O module information
15 14 13 12 11 10
SD1400
0
0
0
SD1401
0
0
0
1
SD1431
0
0
( )
X Y
1FE0
• Not cleared even if the blown fuse is replaced with a new one.
This flag is cleared by error resetting operation.
Explanation
8
7
6
5
4
1
1
0
0
0
0
0
0
0
(Y80)
1
0
0
0
0
0
0
0
0
(Y1A)
1
0
0
0
0
0
0
0
0
(Y1F
B0)
Indicates a blown fuse
8
7
6
5
4
1
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
0
Indicates a blown fuse
Explanation
9
8
6
5
3
7
4
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
( )
X Y
190
0
0
0
0
0
0
0
0
0
0
Indicates an I/O module verification error
Corresponding
Set by
ACPU
(When set)
D9
D9100
D9101
D9102
D9103
D9104
D9105
3
2
1
0
D9106
0
0
0
0
S (Error)
D9107
0
0
0
0
1
0
0
0
(Y1F
30)
3
2
1
0
0
0
0
0
S (Error)
0
0
0
0
1
0
0
0
Corresponding
Set by
ACPU
(When set)
D9
D9116
D9117
D9118
D9119
D9120
D9121
0
2
1
1
D9122
S (Error)
0
0
( )
X Y
0
D9123
0
0
0
0
0
0
MELSEC-Q
Applicable
CPU
+Rem
New
New
New
QCPU
New
Remote
Applicable
CPU
+Rem
New
New
New
App - 41