Mitsubishi QJ71LP21 Reference Manual page 375

Q corresponding melsecnet/h network system melsec-q series
Table of Contents

Advertisement

APPENDIX
No.
Name
SB0069
Multiplex transmission
(105)
designation
3
Multiplex transmission
SB006A
status
(106)
3
Multiplex remote function
SB006B
designation
(107)
3
Baton pass status of each
SB0070
station
(112)
3
Baton pass status of the
SB0071
remote master station
(113)
3
Remote sub-master
SB0072
station transient
(114)
transmission status
3
Cyclic transmission status
SB0074
of each station
(116)
3
Cyclic transmission status
SB0075
of the remote master
(120)
station
3
Remote sub-master
SB0076
station cyclic transmission
(118)
status
3
Remote master station
SB0077
cyclic transmission control
(119)
status
3
Parameter status of each
SB0078
station
(120)
3
Low-speed cyclic
SB007A
communication status
(122)
3
Low-speed cyclic
SB007B
communication status
(123)
3: Valid only when SB0047 is off. When it turns on (error), the last data are retained.
App - 7
Table 1 Special link relay (SB) list (Continued)
Description
Indicates the transmission designation status (status of
supplemental settings of the common parameters).
(Valid when the SB0049 is off.)
Off: Normal transmission designation
On: Multiplex transmission designation
Indicates the transmission status.
Off: Normal transmission
On: Multiplex transmission
Indicates the status of designating the multiplex remote function.
Off: Not designated.
On: Designated.
Indicates the baton pass status of each station. (Not applicable to
reserved stations and the station with the maximum station
number or higher)
Off: All stations normal
On: Faulty station exists
Turns off when the SW0070 to SW0073 are all "0."
Indicates the baton pass status of the master station. (Including
when there is an online loop test.)
Off: Master station baton pass normal.
On: Master station baton pass error.
Indicates the transient transmission status of the remote sub-
master station.
Off: Normal
On: Abnormal
Indicates the cyclic transmission status of each station. (Not
applicable to reserved stations and the station with the maximum
station number or higher)
Off: All stations are executing data linking
On: Stations that are not executing data linking exist
Turns off when the SW0074 to SW0077 are all "0."
Indicates the master station cyclic transmission status. (Includes
online loop test.)
Off: Master station cyclic transmission normal.
On: Master station cyclic transimission error.
Indicates the cyclic transmission status of the remote sub-master
station. (Including the status at an online loop test)
Off: Cyclic transmission normal
On: Cyclic transmission abnormal
Indicates the station type that is controlling cyclic transmission at
the remote I/O stations.
Off: Remote master station
On: Remote sub-master station
Indicates the parameter transmission status of each station. (Not
applicable to reserved stations and the station with the maximum
station number or higher)
Off: Executing communication other than parameter
communication
On: Executing parameter communication
Turns off when the SW0078 to SW007B are all "0."
Indicates the low-speed cycle communication status.
It is indicated to have transmitted by turning the bit on for either
the SB007A or SB007B.
SB007A
SB007B
Cycle interval
MELSEC-Q
Use permitted/prohibited
Remote
Control
Normal
master
station
station
station
Optical Coaxial Optical Coaxial Optical Coaxial Optical Coaxial
Remote I/O
station
App - 7