13C4, 13C5, 13C6, 13C7 - Konica Minolta BIZHUB C3100P Service Manual

Hide thumbs Also See for BIZHUB C3100P:
Table of Contents

Advertisement

Trouble isolation
Relevant electrical parts
Trouble type
Trouble code
Detection timing
Trouble isolation
Relevant electrical parts
Trouble type
Trouble code
Detection timing
Trouble isolation
Relevant electrical parts
Trouble type
Trouble code
Detection timing
Trouble isolation
Relevant electrical parts
(2) Procedure
Step
Check the connector between each sensor-PRCB
1
CN21 for proper connection and correct as necessary.
Replace the toner level sensor of the corresponding
2
color.
3
Replace PRCB.
• Link to the layout drawings for related parts by each trouble code

3.4.14 13C4, 13C5, 13C6, 13C7

(1) Contents
Trouble type
Trouble code
Detection timing
Trouble isolation
Relevant electrical parts
Trouble type
Trouble code
Detection timing
Trouble isolation
Relevant electrical parts
Trouble type
Trouble code
Detection timing
Trouble isolation
Relevant electrical parts
Trouble type
Trouble code
Detection timing
Trouble isolation
Relevant electrical parts
-
• Toner level sensor/Y (PS13)
• Printer control board (PRCB)
Toner level sensor/M malfunction
0F53
An error occurs on the toner level sensor/M.
-
• Toner level sensor/M (PS14)
• Printer control board (PRCB)
Toner level sensor/C malfunction
0F54
An error occurs on the toner level sensor/C.
-
• Toner level sensor/C (PS15)
• Printer control board (PRCB)
Toner level sensor/K malfunction
0F55
An error occurs on the toner level sensor/K.
-
• Toner level sensor/K (PS16)
• Printer control board (PRCB)
Action
Imaging unit/C new article release
13C4
The status with the new unit is not cleared continuously for 3 times after the new imaging unit is set.
-
• Imaging unit/C
• Printer control board (PRCB)
Imaging unit/M new article release
13C5
The status with the new unit is not cleared continuously for 3 times after the new imaging unit is set.
-
• Imaging unit/M
• Printer control board (PRCB)
Imaging unit/Y new article release
13C6
The status with the new unit is not cleared continuously for 3 times after the new imaging unit is set.
-
• Imaging unit/Y
• Printer control board (PRCB)
Imaging unit/K new article release
13C7
The status with the new unit is not cleared continuously for 3 times after the new imaging unit is set.
-
• Imaging unit/K
• Printer control board (PRCB)
K TROUBLESHOOTING > 3. TROUBLE CODE
Control signal
-
-
-
(S.13. 0F52, 0F53, 0F54,
0F55)
K-17
Location of electrical components
-
-
-