7. Install the new fuser unit.
8. From the Menu, select [SERVICE MODE] -> [COUNTER] -> [LIFE] -> [REPLACE] -> [FUSER UNIT] and execute this function to reset the
fuser unit counter value.
I.3.7.1 LIFE-REPLACE-FUSER UNIT
5.4 Feed section
5.4.1 Replacing the manual tray feed roller
(1) Periodically replacing parts/cycle
Manual tray feed roller: Every 300,000 counts
(2) Procedure
1. Remove the manual tray.
G.5.9 Manual tray
2. Open the right door.
[1]
[2]
[1]
[1]
F MANTENANCE > 5. PERIODICAL MAINTENANCE PROCEDURE
5. Pull down two levers [1].
6. Remove the fuser unit [1].
3. Detach the spring [1] from the hook [2] in order to unlock the plate.
4. Remove two springs [1].
F-13