6.0

Power Requirements

Jacuzzi spas are designed to provide optimum performance
and flexibility of use when connected to the maximum electrical
service listed below. Minor circuit board modifications can be
performed to allow your new spa to accept an electrical service other
than the factory operation setting.
Note: Refer to pages 56-60 for circuit board configuration details or
contact your authorized Jacuzzi dealer.
North American J-335, J-345, J-355, J-365, J-375 and J-385 Models
Circuit Breaker (2-Pole):
Number of Wires:
Frequency:
Current Draw:
In 40A configuration, the heater will not operate while either jets
*
pump is running.
** In 50A configuration, the heater will not operate while both jets
pumps are running. This is the factory setting.
*** In 60A configuration the heater will operate while both jets pumps
are running.
North American J-315 and J-325 Convertible Models (60 Hz)
Circuit Breaker:
Number of Wires:
Frequency:
Current Draw:
* In 15A/30A configuration, the heater will not operate while the jets
pump is running. The factory setting is 120V/15A.
** In 40A configuration, the heater will operate while the jets pump is
running.
**CAUTION: (For a 4-wire 240 VAC Heater Operation): Make
certain wires are connected exactly as shown in Figure D (page 18)
before applying power. Failure to do so will result in damage to the
circuit board and/or related components and void the manufacturer's
warranty.
(60 Hz)
240V/40A*
40A
3
60 Hz
26A
120V/15A*
15A, 1-Pole
3 (15A GFCI
4 (Hard Wire
Cord US
Only*)
60 Hz
12A
240V/50A**
240V/60A***
50A
3
60 Hz
37A
240V/30A*
240V/40A**
40A , 2-Pole
30A, 2-Pole
4 (Hard Wire
Only)
60 Hz
20A
J-300
60A
3
60 Hz
48A
Only)
60 Hz
31A