Power Requirements - Jacuzzi J-100 Owner's Manual

Hide thumbs Also See for J-100:
Table of Contents

Advertisement

J-100
6.0

Power Requirements

Jacuzzi spas are designed to provide optimum performance and
flexibility of use when connected to the maximum electrical service listed
below. Minor circuit board modifications can be performed to allow your
new spa to accept an electrical service other than the factory operation
setting.
Note: Refer to pages 36-37 for circuit board configuration details or
contact your authorized Jacuzzi dealer.
All North American J-135/J-145 Models (60 Hz)
Circuit Breaker (2-Pole):
Number of Wires:
Frequency:
Current Draw:
In 40A configuration, the heater will not operate while either jets
*
pump is running in high speed. Note: pump 2 runs only in high
speed.
** In 50A configuration, the heater will not operate while both jets
pumps are running in high speed. This is the factory setting.
Note: pump 2 runs only in high speed.
*** In 60A configuration the heater will operate while both jets pumps
are running in high speed.
Circuit Breaker:
Number of Wires:
Frequency:
Current Draw:
In 20A configuration, the heater will not operate while either jets
*
pump is running in high speed. This is the factory setting. Note:
pump 2 runs only in high speed.
** In 30A configuration, the heater will operate while one jets pump
is running in high speed. Note: pump 2 runs only in high speed.
*** In 40A configuration the heater will operate while both jets pumps
are running in high speed.
12
240V/40A*
40A*
3
60 Hz
26A
Export J-135/J-145 Models (50 Hz)
230V/20A*
20A*
3
50 Hz
15A
240V/50A**
240V/60A***
50A**
3
60 Hz
36A
230V/30A**
230V/40A***
30A**
3
50 Hz
23A
60A***
3
60 Hz
45A
40A***
3
50 Hz
29A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents