Power Requirements - Jacuzzi J-585 Owner's Manual

J-500 collection
Table of Contents

Advertisement

7.0

Power Requirements

Jacuzzi ® spas are designed to provide optimum performance and
flexibility of use when connected to their maximum electrical service.
They are configured at the factory. The most common electrical
connections are listed below. Reference page 73 for dip switch
settings.
All North American 60 Hz Models only: These models come set for
50A logic. If you prefer, your qualified technician can perform a logic
modification that allows the spas to operate on a different electrical
service.
Voltage:
Max. Current Draw:
Frequency:
Number of Wires:
Circuit Breaker (2-Pole):
In 40A configuration, the heater will not operate while either jets
*
pump is running.
** In 50A configuration, the heater will operate when one jets pump
is running, but will not operate while both jets pumps are running.
This is the factory setting.
*** In 60A configuration the heater will operate while both jets pumps
are running.
All Export 50 Hz Models:
Voltage:
Max. Current Draw:
Wattage:
Frequency:
Number of Wires:
In this configuration, the heater will not operate while either jets pump is
*
running. Only one jets pump will operate at a time.
In this configuration, the heater will operate while both jets pumps are
**
running.
Page 16
North American Models (60 Hz)
240 VAC
32A
60 Hz
3
40A*
Export Models (50 Hz)
Single Breaker
Service 1
(including heater)*
230 VAC
17A
3,9 kW
50 Hz
3
240 VAC
240 VAC
40A
60 Hz
3
50A**
Single Breaker
Service 1
(including heater)**
230 VAC
30A
6,9 kW
50 Hz
3
48A
60 Hz
3
60A***