Holding The Measured Values - Konica Minolta CA-310 Instruction Manual

Display color analyzer
Table of Contents

Advertisement

2. Holding the Measured Values

● To hold the measured values, press the HOLD key. The HOLD LED
will light up. (Hold mode)
Pressing the HOLD key again will cancel hold mode and resume mea-
surement. This will cause the HOLD LED to go out.
* If the conditions (e.g. measurement mode) set for hold mode are changed, the measured values
that are currently hold will be re-calculated according to the new conditions and then dis-
played. (This does not apply in the case of SYNC mode.)
<Notes on when Holding the Measured Values>
● It is not possible to hold the measured values in the following cases.
1 Until the measured values appear after the POWER switch is set to ON and then 0-CAL key is pressed
2 Until the measured values appear after the 0-CAL key is pressed
3 When the error message "NO SYNC. SIGNAL" is currently displayed in the LCD display section
● To cancel hold mode, press the 0-CAL key.
3. Displaying the Measured Values
<For xylv, T∆ ∆ ∆ ∆ ∆ uvLv, u'v'Lv or XYZ Mode>
The measurement results will be displayed in the digital and analog display
sections.
● The digital display section shows the measurement results.
All measurement values can be acquired by communicating with PC, how-
ever the display of the main unit always displays measurement values 3 to 5
times / second and does not display all the measurement values.
Please see P. 41 for measuring modes.
According to the selection of number of digits to be displayed (P. 42), an
effective number of 3 or 4 digits will be displayed. However, Correlated Color
Temperature T will always be displayed with an effective number of 3 digits.
For ∆uv, a Color Difference from Blackbody Locus, 0 of the integer will not
be displayed when the value is minus. It will be displayed like "-.0092". Lu-
minance Lv will be displayed to two digits to the right of the decimal.
The range to be displayed for T∆uvLv mode is as follows.
2300
T
20000 (K)
| ∆uv | <0.1
The range to be displayed for Luminance Lv is as follows.
When LED Universal Measuring ø27 Probe(CA-PU32/35) or LED Flicker
Measuring ø27 Probe(CA-P32/35) is connected: Lv 1000(cd/m
When LED Universal Measuring ø10 Probe(CA-PSU32/35) or LED Flicker
Measuring ø10 Probe(CA-PS32/35) is connected: Lv 3000(cd/m
● The analog display section shows the difference between the measured value and the
target color in percentage (%).
• Display contents: ∆x, ∆y, ∆Lv
* For details on the analog display function and how to set the range for each dot, refer to page 69.
● When the analog display range is set to n%
Red
-n×8% or
Below ±n%
lower
Below ±n×2%
Below ±n×4%
Below ±n×8%
Red
Green
+n×8% or
higher
For XYZ mode
2
)
2
)
77
HOLD
HOLD key
HOLD LED
For xyLv or u'v'Lv mode
x
y
Lv
For T∆uvLv mode
T
∆uv
Lv
For u'v'Lv mode
u'
v'
Lv
∆x
∆y
∆Lv
∆x
∆y
∆Lv
∆x
∆y
∆Lv
∆x
∆y
∆Lv
∆x
∆y
∆Lv

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents